Yokogawa EJX930A User Manual
Page 84
![background image](/manuals/360054/84/background.png)
<5. Parameter Summary>
5-2
IM 01C25R02-01E
Function
Label
Item
Contents
Default value Handling
*
1
Device
information
Country
HART 7
Country code
US, JP, DE, FR, ES, RU, CN JP
W
Dev id
Device ID
R
Distributor
Yokogawa
R
Drain vent matl
Drain and vent plug material
W
Extra No.
Customizaion number
R
Ext SW
External zeroing permission
Disabled or Enabled
Enabled
W
Fill fluid
Fill fluid
W
Final asmbly num
Final assembly number
W
Fld dev rev
Field device revision
R
Gasket matl
Gasket material
W
Isoltr matl
Capsule material
W
Mftr Date
Manufactured date
R
Model 1/MS Code 1 Memo field for MS code 1
32 alphanumerics
W
Model 2/MS Code 2 Memo field for MS code 2
32 alphanumerics
W
Model 3/MS Code 3 Memo field for MS code 3
32 alphanumerics
W
Num of RS
Number of remote seal
W
Process Conn matl Process connection material
W
Process Conn size Process connection size
W
Process Conn type Process connection type
W
PT100 Serial No.
Serial number of PT100
W
RS fill fluid
Fill fluid of remote seal
W
RS Isoltr matl
Remote seal material
W
RS type
Remote seal type
W
Serial No.
Serial number
R
Sofftware rev
Software revision
R
Style No.
Style number
Style number of product
R
Universal rev
Universal revision
16 alphanumerics
R
Cfg chng count
HART 7
Configuration change counter
0
R
Reset Cfg chng flag
HART 7
Reset Configuration change flag
M
Device Profile
HART 7
Device Profile
Process
automation
device
R
Max dev vars
HART 7
Max device variables
3
R
Model
Model
Model name + Measurement
span in the Suffix Codes
Ex) “EJX910 M”
R
Device
Variable
Simulation
Simulate
HART 7
Execution of device variable
simulation
Execute the simulation
M
Diag
Applicable
Diag Applicable
Appicable blockage detection
Disabled or Enabled
RG
Diag DPComp Diag DPComp
fDP compensation selection
Compensation or
Non-compensation
Compensation
WG
Diag Error
Diag Error
Results detected by ILBD or Heat
trace monitoring
RG
*1: Handling: R-Read only, W-Read & Write, M-Method, G-Applicable for option code DG6
*2: Max three Burst Messages (Burst Message 1, Burst Message 2, Burst Message 3)