Functional block diagram, Ejx multivariable transmitter – Yokogawa EJX930A User Manual
Page 55
<4. Diagnostics>
4-5
IM 01C25R02-01E
Functional block diagram
The figure below shows the functional block diagram of ILBD.
EJX multivariable transmitter
Sensor
Process Value
calculation
Blockage degree
Alarm
Masking
Response Code
(Device Status)
Status group 9,10
Display on LCD
Contact Output
(Digital Output)
Sensor
signals
DO Config
Ratio fDP
Ratio fSPl
Ratio fSPh
BlkF
fDP
fSPl
fSPh
Diag Applicable*
1
Diag Error
Add result of
blockage detection to status
Pres, SP, ET, Flow,
Total Flow,
Engr Disp, PV %,
Cap temp,
Amp temp
4-20mA DC
(Analog Output)
Execution of
ILBD
Result of blockage detection
Blockage alarm
Blockage alarm
Diag Output
Option
Blockage alarm
Result of blockage detection
-------(6)
F0402.ai
*1: Only for DD(HART 5/HART 7) and DTM(HART 7)
In the case of DTM(HART 5), color of icon in the
Diag Error display changes according to the status.
-------(7)
-------(1)
-------(4)
-------(2)
-------(3)
-------(5)
Figure 4.2
Functional Block Diagram of ILBD
The following outputs are given for the ILBD results.
Table 4.1
List of Outputs for ILBD
OUTPUT
Parameter name
Parameters based on the fluctuation value and blockage degree.
[ Diag DPComp: Non-Compensation ]
:
[ Diag DPComp: Compensation ]
:
Blockage degree characterized in comparison of high-pressure side and low-pressure
side pressure fluctuation value.
Average value of the sum of squares of differential pressure fluctuations.
Average value of the sum of squares of low-pressure side static pressure fluctuation.
Average value of the sum of squares of high-pressure side static pressure fluctuation.
After the reference value is obtained, the applicable blockage defection and the status of
abnormal fluctuation are displayed on this parameter.
When an impulse line blockage is detected, “More Status Avairable” is generated in
Response Code Device Status.
Response Code
Device Status
When an impulse line blockage is detected, the result of the blockage detection
(alarm status) is indicated.
When an impulse line blockage is detected, the results of the blockage detection
(alarm status) is indicated.
When impulse line blockage is detected, an alarm status is displayed on LCD.
When impulse line blockage is detected, an alarm status is output on 4 to 20mA.
When impulse line blockage is detected, an alarm status is output on Status output.
#
(1)
(3)
(4)
Status group 9,10
Diag Error
Ratio fDP
Ratio fSPl
Ratio fSPh
BlkF
(2)
=
Ratio fDP
Ref fDP
fDP
×
DPAvg
Ref DPAvg
=
Ratio fDP
Ref fDP
fDP
=
Ratio fSPl
Ref fSPl
fSPl
=
Ratio fSPh
Ref fSPh
fSPh
Remarks
(5)
(6)
(7)
Display on LCD
Analog Output
Digital Output
fDP
fSPI
fSPh
Diag Applicable*
1
F0403.ai