How To Program the Series 922, Chapter 6

WATLOW Series 922 User's Manual

59

PROGRAM Menu

SEC

( )

MIN

( )

HOUR ( )

One of three main level operating menus. From the SETUP menu,
you can enter or view step type, program loops, wait for conditions,
set points, auxiliary (event) outputs ON/OFF, and step duration.

Represents the current SYSTEM file of the Series 922 to be edited or
reviewed.
Range: 1 to 10 files

Default: 1

Represents the current step of a file of the Series 922 to be edited or
reviewed.
Range: 1 to 99 steps

Default: 1

One of six step types under the PROGRAM menu of the Series 922.
Can be programmed as a file or a step to achieve or maintain a set
point.

Represents the temperature that the system will try to achieve on
Channel 1 in the amount of time given. This will be done linearly,
producing a ramp from a beginning set point to an end set point.
Range: R1L to R1H

Default: Unprogrammed

Represents the temperature that the system will try to achieve on
Channel 2 in the amount of time given. This will be done linearly,
producing a ramp from a beginning set point to an end set point. This
parameter will not appear if the TYP prompt under the SPCLFUNC
menu has been selected as "T" (Temperature for Channel 1 only) or
"P" (Process for Channel 1 only).
Range: R2L to R2H

Default: Unprogrammed

The number of hours, in combination with the MIN and SEC
parameters, that equal the total step time to achieve the temperature
under the SETPOINT step-type.
Range: 0 to 23 hours

Default: Unprogrammed

The number of minutes that equal total step time to achieve the
temperature of the Series 922. Under the SETPOINT step-type.
Range: 0 to 59 minutes

Default: Unprogrammed

The number of seconds that equal total step time to achieve the
temperature of the Series 922 under the SETPOINT step-type.
Range: 0 to 59 seconds

Default: Unprogrammed

This auxiliary output can be an alarm or event. EV1 will only appear
when AUX1 = EV, and the external event board is connected to the
Series 922. Auxiliary outputs can be alarms or events.
Range: OFF or ON

Default: Unprogrammed

OFF = Event OFF

ON = Event ON

EV2 can be an alarm or event. EV2 will only appear when AUX2 =
EV, and the external event board is connected to the Series 922, or
EV2 will appear if T or P in the TYP parameter under the SPCLFUNC
menu have been selected and an external event board is present.
Range: OFF or ON

Default: Unprogrammed

OFF = Event OFF

ON = Event ON

Represents the state the 6 event outputs are forced to when the

SP1

( )

SETPOINT

STEP

( )

F ILE?

( )

Program

Shaded parameters may not appear on your control. They are
dependent on your control configuration.

SP2 ( )

EV1 ( )

EV2 ( )