2 performance specifications, 1 general specifications -2 – Proface GP4100 - 3.4 Compact HMIs" User Manual
Page 33
GP-4100 Series Hardware Manual
3-4
3.1.2
Performance Specifications
Performance Specifications
GP4104
GP4105
GP4106
GP4107
Application
Memory
*1
*1
Capacity available for user application.
FLASH EPROM 2.2 MB
Logic Program Area
None
Font Area
None
Data Backup
FLASH EPROM 128KB
*2
*2
Stores the Alarm History Data, Recipe Data, and Brightness/Contrast Control Settings.
Variable Area
None
Clock Accuracy
Uses the clock of an external device
*3
*3
Set up the “Clock Updates“ feature with the Editor software. Please refer to the GP-Pro EX
Reference Manual “Common” - “Clock Update Settings” for details.
Interface
Serial (COM1)
–
RS-232C
Asynchronous
Transmission
Data Length: 7
or 8 bit
Parity: none,
Odd or Even
Stop Bit: 1 or 2
bit
Data
Transmission
Speed: 2,400
bps to 115.2
kbps
Connector: 2-
piece terminal
block 9 pin
RS-422/485,
Asynchronous
Transmission
Data Length: 7
or 8 bit
Parity: none,
Odd or Even
Stop Bit: 1 or 2
bit
Data
Transmission
Speed: 2,400
bps to 115.2
kbps
Connector: 2-
piece terminal
block 9 pin
RS-485
(isolation)
Asynchronous
Transmission
Data Length: 7
or 8 bit
Parity: none,
Odd or Even
Stop Bit: 1 or 2
bit
Data
Transmission
Speed: 2,400
bps to 115.2
kbps, 187.5
kbps (MPI)
Connector: D-
Sub9 (socket)
Ethernet
IEEE802.3u,
10BASE-T/
100BASE-TX,
Connector:
Modular jack
(RJ-45) x 1
–
–
–
USB
(Type-A)
*4
*4
If connecting a bar code reader to the GP, be sure to supply power from an external source
(such as a self-powered hub). If you supply power from the GP, the GP may reset itself
because the GP cannot supply enough power.
Conforms to USB2.0 (TYPE-A) x 1
Power Supply Voltage: DC5V ±5%
Communication Distance: 5 m or less
USB (mini-B)
Conforms to USB2.0 (mini-B) x 1
Communication Distance: 5 m or less