beautypg.com

Typical hydraulic layout, Provided by user, Hydraulic system requirements – Ramsey Winch H-89 User Manual

Page 12

background image

12

HYDRAULIC SYSTEM REQUIREMENTS

1. Motor spool (open center) control valve.
2. Emergency Stop:

A. If winch is controlled by a direct-operated manual valve, that valve serves as the

E-stop.

B. If a remote operated control valve is used, a solenoid-operated hydraulic dump

valve, normally open to tank, and an emergency stop switch (to open the dump
valve) is required. The E-stop switch is to be normally closed and have a red,

resettable push button actuator with a yellow background. The E-stop switch

must be easily accessible to the operator.

3. “A” port motor control valve rated for a maximum flow of 114 LPM (30 GPM).
4. Hydraulic motor with a volume of 244 cc (14.9 cu in)/rev.
5. Relief valve set to 151,7 bar (2200 psi) which is the rated capacity limiter.
6. Flow rate of 114 LPM (30 GPM) maximum.
7. Hydraulic fluid with a viscosity between 20-43 cSt (100-200 SUS). Maximum operating
temperature 85C (180F). Cleanliness level of ISO 17-14 or better.

Note: Some models are sold without the hydraulic motor and “A” port motor control valve.
It is the User’s responsibility to meet the following meet the Hydraulic System
Requirements.

(RATED CAPACITY LIMITER)

151,7 bar (2,200 PSI)

114 LPM (30 GPM)

33 mm (1.31 in) I.D. MINIMUM

I.D. MINIMUM

22 mm (.88 in)

PUMP

LOW PRESSURE LINE

HIGH PRESSURE LINE

RATED LOAD:

PRESSURE AT

MAX. FLOW &

(MOTOR SPOOL)

4 WAY VALVE

3 POSITION

SYSTEM RELIEF

PROVIDED BY USER

DUMP VALVE

*

*

E-STOP SWITCH

REQUIRED ONLY IF REMOTE-OPERATED CONTROL VALVE IS USED. SEE 2B

*

IN HYDRAULIC SYSTEMS REQUIREMENTS. NOT REQUIRED FOR A
DIRECT-OPERATED MANUAL VALVE.

A PORT

MOTOR CONTROL VALVE

TYPICAL HYDRAULIC LAYOUT

WINCH MOTOR

HYDRAULIC

151,7 bar (2,200 PSI)

12/28/2013