beautypg.com

2 serial port 8 configuration – IEI Integration TANK-700-QM67 v2.00 User Manual

Page 72

background image

TANK-700 Em b e d d e d S ys te m

P a g e 60

 Device Mo d e [No rm al]

Use the Device Mode option to enable or disable the serial port.

Normal

D

EFAULT

Sets the serial port mode to normal.

RS422/485

Enables serial port RS-422/485 support.

4.3.6.1.2 S e ria l P o rt 8 Co n fig u ra tio n

 Serial Po rt [En ab led ]

Use the Serial Port option to enable or disable the serial port.

Disabled

Disable the serial port

Enabled

D

EFAULT

Enable the serial port

 Ch an g e S ettin g s [Au to ]

Use the Change Settings option to change the serial port IO port address and interrupt

address.

Auto

D

EFAULT

The serial port IO port address and interrupt address

are automatically detected.

IO=2F8h;

IRQ=3

Serial Port I/O port address is 2F8h and the interrupt

address is IRQ3

IO=3F8h;

IRQ=3, 4, 5,

6, 7, 9, 10,

11, 12

Serial Port I/O port address is 3F8h and the interrupt

address is IRQ3, 4, 5, 6, 7, 9, 10, 11, 12

IO=2F8h;

IRQ=3, 4, 5,

6, 7, 9, 10,

11, 12

Serial Port I/O port address is 2F8h and the interrupt

address is IRQ3, 4, 5, 6, 7, 9, 10, 11, 12