TANK-700 Em b e d d e d S ys te m

P a g e 43

3.11.1.2 S witc h to Ba c ku p P o we r

During operation, system power will switch from Power 1 to Power 2 automatically when

the following situations occur:

 Power 1 < 9V and Power 2 > 10.5V

 Power 1 > 9V, but the ACC ON signal jumps from high to low

 Power 1 is unplugged and Power 2 > 10.5V

The following flow diagram shows how the power is switched between Power 1 and

Power 2 and their LED statuses.

Figure 3-37: ACC On: Switch Between PWR1 and PWR2

3.11.1.3 S h u td o wn

The system will shutdown in the following situations:

 Power 1 < 9V and Power 2 < 10.5V

 Power 1 > 9V, Power 2 < 10.5V and ACC ON signal jumps from high to low

 Press Power button for 6 seconds

The following flow diagram shows the system shutdown process and the LED statuses.

Figure 3-38: ACC On: Shutdown