KB Electronics IODA, Input/Output Module for use with all KBDA/KBMK Controls User Manual
Page 30

30
TABLE 16
ANALOG INPUT "2" ELECTRICAL RATINGS
Parameter Specification
Factory
setting
Voltage Range (Volts DC)
0 – ±2.5 thru 0 – ±25
0 – 5
MAX2 Scaling Trimpot Range (Volts DC)
0 – 24
5
Current Range (mA DC)
0 – 20*
–
Input Impedance for Current Mode (
Ω) 270
–
PWM (kHz, Duty Cycle)
0.15 – 1, 0 – 100
–
*If using 4 – 20 mA DC signal input, the offset setting in Function No. 9.07 must be increased
from "0%" (factory setting) to "20%". Set Jumper J1 to the "CUR" position.
FIGURE 23
ANALOG INPUT "2" SIGNAL CURRENT FOLLOWING CONNECTIONS
+
TABLE 17
ANALOG INPUT "2" SIGNAL CURRENT FOLLOWING PROGRAMMING
Function No.
Code/Range
2.00: Frequency Control 0003:
Analog Signal 2
9.05: Analog Input 2 Gain 0
–
500:
Set to the Desired Gain
7.04: Multi-Function Input Terminal 5
0010: N.O. Start*
9.06: Analog Input 2 Slope
0000: Positive
0001: Negative
9.07: Analog Input 2 Offset 0
–
100:
Set to the Desired Offset
9.08: Analog Input 2 Type
0000: Analog Voltage or Current
9.09: Analog Input 2 Response Time (mSec) 2 – 100: Set to the Desired Time
*Factory setting.