5. Maintenance Inspection
5.1
Inspection Items and Inspection Schedule
Have maintenance inspections following the intervals below.
The calculation is conducted under the condition that there are 8 working hours per day. Have
inspections more frequently if the operation frequency is high for night and day continuous operation,
etc.
Visual Inspection
Internal Check
Grease supply
*1
At startup inspection
{
1 month after start of
operation
{
6 months after start
of operation
{
{
1 year after start of
operation
{
{
{
Every 6 months
thereafter
{
Every 1 year since
{
{
{
*1
If the actuator is operated back and forth repeatedly over a distance of 30 mm or less, the oil film
created by the grease may be broken. It is recommended to have 5 cycles of back and forth
operation in a distance more than 50mm after every 5,000 to 10,000 rounds of the short distance
operation. A layer of the grease will recover.
5.2 Visual
inspection
For the visual inspection, check the appearance following items.
Main Body
Looseness of attachment screws
Cables
Scratches, proper connection of connectors
Overall Noise,
vibration
5.3 Cleaning
x Please clean the external body on a regular basis.
x When cleaning, wipe with a soft cloth to remove dust and dirt.
x The base oil of the grease may come out on the surface of the actuator in some cases. Wipe it
away with soft cloth.
x There is a risk of dust getting in from a clearance. Do not blow compressed air strongly to the body.
x Do not apply petroleum solvent since it may damage the resin or painted surfaces.
x When extremely dirty, wipe it off firmly with cloth that a neutral detergent or alcohol is applied on.