6 tank leak sensor models jt-2p and 2v – Ronan X76CTM User Manual
Page 23
22
Switch:
Type:
DPDT, N.C. top, N.O. bottom.
Rating:
10 VA.
Float Material:
Polysulfone.
Pressure:
50 psi maximum.
Leads:
20 AWG.
Application:
Vertical position high/low level.
detection, 4 in. separation.
Approvals:
UL Listed 48RO.
11.6 Tank Leak Sensor Models JT-2P & 2V
Sensor Housing: Aluminum body with ¼ in.
stainless steel inlet, explosion proof, hermet-
ically sealed, NEMA types 7 and 9.
Manifold:
Brass, 1 in. NPT male thread
(JT-2P, JT-2V).
Classification:
Class I, Groups A, B, C, and
D; Class II, Groups E, F, and G.
Switch:
Type:
SPDT, N.O. (shelf condition).
Rating:
10 VA.
Electrical Connection:
½ in. NPT with PVC
insulated 18 AWG color coded leads.
Pressure:
Connection:
¼ in. NPT.
Adjustment:
Allen wrench through port.
Proof Pressure:
299 psi.
Gauge:
0-30 psi (JT-2P), 0-20 in. Hg (JT-2V).
Temp. Range:
-40 to 180°F (-40 to 82°C).
Approvals:
UL Listed 48RO.