0 specifications, 1 model x76ctm system, 2 gauging probes, models 95040xb and 95140xb – Ronan X76CTM User Manual
Page 22: 3 leak sensors, models ls-3, ls-3s, and ls-3ss, 4 tank leak sensors, models ls-7, and ls-7s, 5 hydrostatic leak sensor, model ls-30
21
support the floating point format. Although
the Modbus™ register in the Read Multiple
Registers Command (03) is 16 bit wide,
each floating point or unsigned long number
will occupy 2 registers. The register alloca-
tions for the tanks are shown in the table
on page 20.
The last registers are reserved for future
use. The data for the next tanks occupy the
next 350 registers at 50 registers per tank,
with the same register allocations
11.0 SPECIFICATIONS
11.1 Model X76CTM System
Power Requirements:
115/230 Vac,
50/60 Hz ±10%.
Power Consumption:
50 VA.
Operating Temp.:
32 to 125°F (0 to 52°C).
Mounting:
NEMA 4, indoor or outdoor area,
wall mount.
Display:
Alphanumeric LCD, 2 lines x 24
characters per line.
Probe Inputs:
One (1) to eight (8).
Sensor Inputs:
Up to 16 passive inputs
24 Vdc, 12 mA.
Remote Communication Ports:
Two (2)
RS232C Serial Interface Ports.
Auxiliary Relay Outputs:
Four (4) SPDT,
120 Vac max., 7.5 A max.
Data Entry Keypad:
Three section mem-
brane.
Printer:
Alphanumeric paper, impact, 2¼ in.
wide x 75 ft. (24 characters wide).
Dimensions:
12 in. W x 15½ in. H x
6-3/32 in. D.
Alarms:
LED & Sonalert; 80db @ 10 ft.
(115 Vac power only).
Approvals:
UL 48RO.
11.2 Gauging Probe, Model 95040XB
and Model 95140XB
Power Requirements:
24 Vdc intrinsically
safe, pulsed, supplied by control chassis.
Operating Temperature:
-40 to 130°F
(-40 to 54°C) (consult factory for other
temperature ranges).
Probe Material:
316 stainless steel (consult
factory for other material types).
Float Material:
Ceon-D, X95040XB; 316SS,
95140XB.
Repeatability:
.02% or full range.
Accuracy:
.05% of full range.
Resolution:
± .001 in.
Site Characteristics:
4 in. schedule 40 riser.
Wiring:
Two (2) conductor shielded cables,
max. length 2500 ft.
Approvals:
UL Listed 48RO, intrinsically safe
for use in hazardous locations, Class I, Div.
1, Groups C & D; Class II, Div. 1, Groups E,
F, & G; Class III, Div. 1.
11.3 Leak Sensor, Models LS-3, LS-3s,
and LS-3ss
Housing:
304 stainless steel.
Mounting:
½ in. NPT male thread.
Switch:
Type:
SPST, N.O. or N.C.
Rating:
10 VA.
Float Material:
Buna-N (LS-3, LS-3s).
316 stainless steel (LS-3ss).
Pressure:
50 psi maximum.
Leads:
20 AWG.
Test Mechanism:
Stainless steel cable
(LS-3s).
Application:
Vertical position liquid detection.
Approvals:
UL Listed 48RO.
11.4 Tank Leak Sensor, Model LS-7,
and LS-7s
Housing:
PVC.
Liquid Specific Gravity:
70 minimum.
Switch:
Type:
SPST, N.C.
Rating:
10 VA.
Float Material:
PVC.
Pressure:
50 psi maximum.
Leads:
20 AWG.
Test Mechanism:
Stainless steel cable
(LS-7s).
Application:
Horizontal position liquid
detection.
Approvals:
UL Listed 48RO.
11.5 Hydrostatic Leak Sensor,
Model LS-30
Housing:
304 stainless steel.
Mounting:
½ in. NPT male thread.