beautypg.com

Ronan X76CTM User Manual

Page 11

background image

10

.

.

46, Date & Time Format [HI, LO]
(Y2K Compliant)

Use this function to set up the time and date for-
mat. Use the [HI] and [LO] keys to scroll through
the selections.

Date & time format (HI,LO): 1
mm/dd/yy

hh:mm:ss

AM/PM

The X76CTM can operate with date and time in
different formats, to adapt for different countries.
The formats supported are:

1. mm/dd/yy hh:mm:ss US

style

2. mm/dd/yyyy hh:mm:ss

Displays full year,
US style

3. mm/dd/yy hh:mm:ss

AM/PM, US style

4. dd-mm-yy hh:mm:ss

European style

5. dd-mm-yyyy hh:mm:ss

Displays full year,
European style

6. dd/mm/yy hh:mm:ssEuropean style

7. dd/mm/yyyy hh:mm:ss

Displays full year,
European style

.

.

91, Enter Date & Time

To set the time and date, use Function 91. With
the X76CTM, both the date and time can be
entered using this function. When entering the
time, it must be entered in military format (24
hours). Use the [HI] and [LO] keys to advance
the cursor to the corresponding digit.

Enter the date & time
03/02/98 15:18:49

.

.

93, Select Units to Use

The X76CTM defaults to US units. To change the
unit type, use Function 93. Enter the digit cor-
responding to the following choices:

Select units to use
1-US

2-Imperial 3-Metric

.

.

74, Tank Model [HI, LO]

The X76CTM has a predefined table of most of
the industry standard tanks strap charts (Owens-
Corning and Xerxes models). Press Function 74,
[ENT.] to generate the strap chart table.

Tank Model (HI,LO)_1
0/C2 (4) 1000 Owens-Corning

The X76CTM displays the following strap chart table.

User defined
0/C2 (4) 1000 Owens-Corning
0/C2 (6) 2500 Owens-Corning
0/C2 (6) 4000 Owens-Corning
0/C2 (6) 6000 Owens-Corning
0/C2 (8) 6000 Owens-Corning
0/C2 (8) 8000 Owens-Corning
0/C2 (8) 10000 Owens-Corning
0/C2 (8) 12000 Owens-Corning
0/C2 (10) 15000 Owens-Corning
0/C2 (10) 20000 Owens-Corning
0/C2 (10) 25000 Owens-Corning
0/C2 (10) 30000 Owens-Corning
X2 (4) 1000 Xerxes
X2 (6) 2500 Xerxes
X2 (6) 4000 Xerxes
X2 (6) 6000 Xerxes
X2 (8) 8000 Xerxes
X2 (8) 10000 Xerxes
X2 (8) 12000 Xerxes
X2 (10) 15000 Xerxes
X2 (10) 20000 Xerxes
X2 (10) 25000 Xerxes
X2 (10) 30000 Xerxes

For standard tanks where the strap table is known,
select 6, User Types.

Select shape (HI,LO)_6
User types

For non-standard tanks select from the following
shapes at the User Defined option:

1-Flat-end

(for steel tanks)

2-Round-end

(for fiberglass)

3-Vert. cyl
4-Spherical
5-Rectangular

Upon this selection, the strap table editing function
automatically begins.

1. Enter the tank internal diameter.

2. Enter the actual capacity.

3. Select one of the 2 choices for the tank tilt using

[C/CE].

4. If the tank is tilted, enter the probe location (1

for probe between the fill opening and the
center, 2 for fill opening between the probe and
the center).

5. Enter the distance between the probe and the

fill openings.

6. Enter the distance between the probe opening

and the center of the tank.