Report 8 (Cont.)
Report 9:
Contacts Settings.
Report 10:
Relays Settings.
Horn:
No
Scripts:
Normal: none
Alarm: none
X110: 7
on QuickTest
Relay: none
Horn:
Yes
Scripts:
Normal: none
Alarm: none
X110: 8
on PreciseTest
Relay: none
Horn:
Yes
Scripts:
Normal: none
Alarm: none
X110: 8
on HiLeak
Relay: none
Horn:
Yes
Scripts:
Normal: none
Alarm: none
X110: 8
on Csld
Relay: none
Horn:
Yes
Scripts:
Normal: none
Alarm: none
X110: 8
Ronan Engineering LDM
21200 Oxnard Street
Woodland Hills CA 91367
** Contacts settings **
** 08/06/99 10:29:20 **
1 SupPipeSump
State: Normal
Logic: Norm.Open
Relay: SuperPSD
2 SupFullSump
State: Normal
Logic: Norm.Open
Relay: SuperPSD
3 SupAnnular
State: Normal
Logic: Norm.Open
Relay: SuperPSD
4 RegPipeSump
State: Normal
Logic: Norm.Open
Relay: UnleadedPSD
5 RegFullSump
State: Normal
Logic: Norm.Open
Relay: UnleadedPSD
6 RegAnnular
State: Normal
Logic: Norm.Open
Relay: UnleadedPSD
7 RegPipeSump
State: Normal
Logic: Norm.Open
Relay: RegularPSD
8 RegFullSump
State: Normal
Logic: Norm.Open
Relay: RegularPSD
9 Probe input
10 Probe input
11 Probe input
12 RegAnnular
State: Normal
Logic: Norm.Open
Relay: RegularPSD
13 Disp#1
State: Normal
Logic: Norm.Open
Relay: none
14 Disp#2
State: Normal
Logic: Norm.Open
Relay: none
15 Disp#3
State: Normal
Logic: Norm.Open
Relay: none
16 Spare
State: Normal
Logic: Norm.Open
Relay: none
Ronan Engineering LDM
21200 Oxnard Street
Woodland Hills CA 91367
*** Relays settings ***
** 08/06/99 10:29:27 **
1 SuperPSD
State: Open
Logic: Norm.Open
Timeout: 0 s
2 UnleadedPSD
State: Open
Logic: Norm.Open
Timeout: 0 s
3 RegularPSD
State: Open
Logic: Norm.Open
Timeout: 0 s
4 RemoteCTA
State: Closed
Logic: Norm.Closed
Timeout: 30 s
normally closed), current
state (alarm/normal), and
the relay to be activated
depending on the contact
state. This report prints the
settings for all contacts,
including the level gauge
probe inputs.
10.
Relays Settings.
Prints
the current settings for the
76CTM relays. For each re-
lay (total of 4 relays) the
current state, logic (normal-
ly open/normally closed)
and the time-out is report-
ed. If the time-out is 0, the
relay will stay in this state
until changed.The time-out
option is for unattended
stations, to increase the
external horn life, if
attached or in applications
where a plulse is required
for remote alarm indication
of multiple alarms (reflash).
.
.
292, Enable Theft
Monitor
The theft alarm is defined as
the activity of the tank (sale or
withdrawal) when the tank is
declared as inactive. To start
theft monitoring, use Function
292. The current net volume is
recorded and the system moni-
tors the net volume for changes.
If the net volume decreases
more than the threshold value
(default 10 gal), a theft alarm is
generated. The net volume
change will be recorded. For
every occurrence, the amount is
recorded, until the function is
disabled. The theft monitoring
can be disabled using Function
291.
10.1 Setting the User Pin
For security purposes,
the X76CTM is designed
so that only the adminis-