Agilent Technologies E1300B User Manual
Page 176
![background image](/manuals/33541/176/background.png)
:COMMunicate
:SERial[n]:TRANsmit
:PACE [:PROTocol]
SYSTem:COMMunicate:SERial[ n] :TRANsmit:PACE[ :PROTocol]
< protocol> enables or disables the transmit pacing (XON/XOFF) protocol.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
protocol
discrete
XON| NONE
none
Comments
•
For an Agilent E1324A, AUTO is always ON. In this case
…
TRAN:PACE will also set
…
[RECeive]:PACE
•
Receipt of an XOFF character (ASCII 19
10
, 13
16
) will hold off
transmission of data until an XON character (ASCII 17
10
, 11
16
) is
received.
•
DIAG:BOOT:COLD will set
…
PACE to XON.
•
Related Commands: SYST:COMM:SER[n]:TRAN:AUTo
•
*RST Condition: No change
Example
Set XON/XOFF transmit pacing
SYST:COMM:SER0:TRAN:PACE:PROT XON
:COMMunicate
:SERial[n] :TRANsmit
:PACE [:PROTocol]?
SYSTem:COMMunicate:SERial[ n] :TRANsmit:PACE[ :PROTocol] ? returns
the current transmit pacing protocol.
Example
Check transmit pacing protocol
SYST:COMM:SER0:TRAN:PACE:PROT?
enter statement
statement enters the string
"XON" or "NONE"
:DATE
SYSTem:DATE < year> ,< month> ,< day> sets the E1300/E1301
mainframe’s internal calendar.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
year
numeric
must round to 1980 to 2079
none
month
numeric
must round to 1 to 12
none
day
numeric
must round to
1 through last day of month
none
Comments
•
The upper limit on the day parameter is dependent on the month
parameter and may be dependent on the year parameter in the case of a
leap year.
SYSTem:COMMunicate :SERial[n]:TRANsmit :PACE [:PROTocol]
7-48 System Instrument Command Reference