Agilent Technologies E1300B User Manual
Page 173
•
The following table defines each value of type:
Value
Definition
EVEN
If
…
PARity:CHECK is ON, the received parity bit
must maintain even parity. The transmitted parity
bit will maintain even parity.
ODD
If
…
PARity:CHECK is ON, the received parity bit
must maintain odd parity. The transmitted parity
bit will maintain odd parity.
ZERO
If
…
PARity:CHECK is ON, the received parity bit
must be a zero. The transmitted parity bit will be a
zero.
ONE
If
…
PARity:CHECK is ON, the received parity bit
must be a logic one. The transmitted parity bit will
be a logic one.
NONE
A parity bit must not be received in the serial data
frame. No parity bit will be transmitted.
•
While this command operates independently of either the
…
BITS or
…
SBITs commands, there are two combinations which are disallowed
because of their data frame bit width. The following table shows the
possible combinations:
…
BITS
…
PARity:TYPE
…
SBITs
Frame Bits
7
NONE
1
9 - disallowed
7
NONE
2
10
7
Yes
1
10
7
Yes
2
11
8
NONE
1
10
8
NONE
2
11
8
Yes
1
11
8
Yes
2
12 - disallowed
•
Received parity will not be checked unless
…
PAR:CHEC ON is has been
sent. Transmitted data will include the specified parity whether
…
PAR:CHEC is ON or OFF.
•
DIAG:BOOT:COLD will set
…
PARity to NONE.
•
Related Commands:
…
PAR:CHEC 1 | 0 | ON | OFF,
…
SER[n]:BITS 7 | 8,
…
SER[n]:SBITs 1 | 2
•
*RST Condition: No change
Example
Set parity check/generation to ODD.
SYST:COMM:SER0:PAR ODD
Set parity type
SYST:COMM:SER0:PAR:CHEC ON
Enable parity check/gen.
SYSTem :COMMunicate: SERial[n] [:RECeive] :PARity [:TYPE]