:PULSe:PERiod
SOURce:PULSe:PERiod < period> sets the period of the pulse(s) to be
generated by the Pacer.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
pweiod
numeric
500E-9 to 8.388607 or
MIN| MAX
second
Comments
•
The resolution of period is 500E-9 seconds.
•
The Pacer waveform is a square wave with the output high for the first
half of the period, and low for the final half.
•
Related Commands: SOUR:PULS:COUN, ABORT, INIT,TRIG
•
*RST Condition: SOUR:PULS:PER 1E-6
Example
Setting the Pacer pulse period.
TRIG:SOUR HOLD
trigger source is TRIG
command
SOUR:PULS:COUN 1E3
output 1000 Pacer pulses
SOUR:PULS:PER .1 S
pulse period set to .1 second
INIT
go to Wait For Trigger state
TRIG
trigger the Pacer to output
pulses
:PULSe:PERiod?
SOURce:PULSe:PERiod? [ MIN | MAX] returns :
•
The current period if no parameter is sent.
•
The maximum allowable period if MAX is sent.
•
The minimum allowable period if MIN is sent.
Example
Querying the Pacer pulse period.
SOUR:PULS:PER?
ask for pulse period
enter statement
statement to enter value of
period