37

Loops

Safety and Exit Loop Position Diagram























Proper wiring of two loops performing the same function

Example: Inside and Outside Safety Loops


Typical Loop Saw cut - top view








Side view




OUT

GATE IN OPEN POSITION

6 X 12 SAFETY LOOP

6 X 12 SAFETY LOOP

Loop located 4 feet
from gate track

Loop located 4 feet
from gate track

6 X 12 EXIT LOOP

8 feet

Gate track

Operator

Drive 20 feet

1/8”
minimum

¼” minimum

Lead in slot
to operator

Corners should be crosscut as shown for
stress relief. 45 degrees is maximum turn
angle allowed. Saw cut width must be at
least 1/8” for recommended wire. Lead
in slot must be at least ¼” for twisted
leads.

1 ½” Depth

Pavement

¼” Saw cut

3/16” Saw cut

¼” minimum
backfill

Siliconized caulk
preferred

Lead from first loop

Lead from second loop

Detector