Monthly service, Troubleshooting introduction – Controlled Products Systems Group PATRSL User Manual
Page 25
23
MONTHLY SERVICE
All gate operators require periodic checking and adjustments by a qualified technician of the control
mechanism for force (load), speed and sensitivity. All external accessories and secondary safety
devices must be checked. Secondary safety devices need to be checked at least once a month for
proper operation.
Periodic checking is also advised for the following:
1.
Battery cells water level. (use distilled water if needed) Gel batteries are recommended
2.
Wheels and gate rollers for wear and grease if necessary.
3.
Check bolts and sprocket set screws for correct tightness.
4.
Inspect weld points for cracks or other defects.
5.
Inspect wiring for cuts, nicks or other defects.
6.
Inspect drive chain and sprockets for tension and wear. Adjust or replace as necessary.
7.
Time to open or close the gate, this will be first indication of a battery or charging problem.
Troubleshooting Introduction
The USAutomatic control board is equipped with three unique features to assist in
troubleshooting a gate system.
1. The first and most helpful is the series of LED indicating lights. These lights will help to
identify problems with the limit switches and all control circuits. To use the indicators,
press and hold the LED indicator button on the control board. (The lights are not active at
all times to save battery life). Any circuits or limit switches that are activated will be
identified by the illumination of the adjacent LED indicating light.
2. The second feature to assist in troubleshooting is the current sense beeper. The beeper
will sound anytime the current sense circuit is activated. This is useful in detecting a
false reverse due to an improper or too sensitive current reverse setting or a gate that is
requiring excessive force to move.
3. The third feature to assist in troubleshooting is the on board open/close command
pushbutton. This button makes it possible to operate the gate with the twelve terminal
wiring plug removed without having to short across terminal pins.
Siren Output
OPEN/CLOSE
COMMAND
Vehicular Gate Operator
Gate Weight Max. Load: 650 lbs.
LED INDICATOR
S2
RESET
Entrapment
S
E
C
U
R
I
T
Y
S
H
U
N
T
C
O
M
M
O
N
G
N
D
M
A
G
L
O
C
K
S
O
L
O
N
O
I
D
L
O
C
K
C
O
M
M
O
N
G
N
D
O
U
T
P
U
T
+
1
2
V
O
N
2
3
4
1
SOLONOID LOCK ENABLE
MAGNETIC LOCK ENABLE
SECURITY SHUNT ENABLE
MOTION DETECTOR ENABLE
15
5
0
10
TIMER TO CLOSE
ADJUSTMENT
Timer
ADJUSTMENT
Class I or Class II per UL325
J2
INDICATORS
1-
+12V OUT 1.5 AMP MAX
2- COMMON
GROUND
3-
PUSH BUTTON INPUT
4-
OPEN SAFETY EDGE
5- CLOSE
INPUT
6-
SECONDARY ENTRAPMENT DEVICE INPUT
7- COMMON
GROUND
8-
STOP CIRCUIT INPUT N/C
9-
FREE EXIT / OPEN INPUT
10-
UNDER GATE / CENTER LOOP INPUT
11-
SAFETY LOOP / REVERSING EDGE INPUT
12-
MOTION DETECTOR INPUT
1
2
3
4
5
6
7
8
9 10 11 12
J2
BOTH ON FOR DUAL
DS1 SWITCH SETTINGS
FACTORY SETTINGS
SW-1
AUTO CLOSE TIMER ENABLE
OFF
SW-2
TIMER TO CLOSE WILL ACTIVATE ON LIMIT ONLY
ON
SW-3
MASTER GATE ENABLE
ON
SW-4
SLAVE GATE ENABLE
OFF
SW-5
SOLENOID LOCK OPTION, SEE INSTALLATION MANUAL
OFF
SW-6
SOFT STOP RETRACT ENABLE
OFF
SW-7
SOFT STOP EXTEND ENABLE
OFF
SW-8
STOP CIRCUIT ENABLE
OFF
SW-9
OPERATING DIRECTION REVERSE
OFF
SW-10
SOFT START ENABLE FOR SW6 AND SW7
OFF
1
2
3
4
5
6
7
8
9
10
O
N
DS1
PATRIOT CONTROL BOARD
USAutomatic
MADE IN USA
CURRENT SENSE
ADJUSTMENT
0
10
5
MASTER
Sensitivity
CURRENT SENSE
ADJUSTMENT
0
10
5
SLAVE
Sensitivity
15
Current Sense
Beeper
LED indicator
button
LED indicators J2
Open/Close
command push
button
LED indicators for
master /Slave limits.
Master Close limit
Master Open limit
Slave Close limit
Slave Open limit