beautypg.com

Controlled Products Systems Group PATRSL User Manual

Page 31

background image

29

STEP 5

Go to page 33 “Resetting receiver P2 relay to momentary mode”

STEP 6

If this does not correct the problem return to troubleshooting section 5 and perform steps 1-6.

STEP 7

If problem is not corrected, call the factory for further troubleshooting.

15. Gate only operates when the “LED INDICATOR” is pressed.

STEP 1

An accessory wiring problem or a bad control board can cause this, this problem can be intermittent and possibly take
a little patience in locating the problem.

STEP 2

Verify that the problem exist when using the “Open /Close Command” on the control board. Press the “Open/Close
Command” push button and verify gate will not operate.

STEP 3

Press and hold the “Led Indicator” on the control board then press the “Open/Close Command” push button on the
control board. If the gate operates proceed to step 4.

STEP 4

Remove the J2 accessory-wiring plug from the control board. This connector can be disconnected from the control
board by placing a finger under the plug and pulling to remove.

STEP 5

Press the “Open/Close Command” push button and verify gate operation. If gate operates then reconnect the J2
connector and verify gate operation using the “Open/Close Command” push button. If gate fails to operate when the
J2 connector is reconnected then the problem is most likely in the accessory wiring, a bad ground connection on the
accessory. Verify all wiring on the accessories connected to the J2 connector.

STEP 6

If gate fails to operate when the J2 connector is disconnected then the control board is most likely the problem. Please
contact the factory for further troubleshooting options.

NOTE:

Keep in mind that this is an intermittent problem and it might be necessary to try this a few times to verify the
problem.