14
STEP 9 Making Final Adjustments
Once gate is operating correctly using the “Open / Close Command” pushbutton it is time to setup the radio
controls, transmitter and receiver. If your operator was supplied with the low current receiver see page 33 for
programming instructions. If not see instructions for your specific radio controls.
If you have an understanding of the sensitivity feature, test the sensitivity by manually stopping the gate in mid
travel. The sensitivity setting most likely will be around a 5 or 7 setting on the adjustment.
Operate the gate using the transmitter, the gate should stop in the desired position if not readjust the limit
switches. If the transmitter is not operating or operating incorrectly reprogram transmitter and receiver.
STEP 10 Installing Secondary Entrapment Siren
(UL-325 requirement)
The secondary entrapment siren connects to the control board (Page 12, illustration 17). This siren is very loud
and will be activated when the current sense circuit stops the gate twice prior to reaching a fully open or close
limit. The siren will operate for 5 minutes before shutting off. The “Reset” button on the control board (Page 12,
illustration17) can be pushed to turn off the siren, and reset the control board. The control board must be reset
using the “Reset” button in either case before the gate will operate. The frame has two pre-punched holes below
the control board use these to secure the siren in place using the two snap in plastic fasteners.
STEP 11 Installing Safety Placards
(UL-325 requirement)
Mount safety placards on gate. Two signs are provided. Place one sign on each side of the gate where it will be
highly visible to anyone on either side of the gate.
STEP 12 Installing Cover
Locate the emergency release access cover (round cover with USAutomatic logo), the shoulder screw and nut.
Install screw through emergency release access cover and install onto operator cover using the supplied nut.
Tighten nut securely.
Place the cover over the operator with the emergency release knob visible through the access hole. Secure in
place using the 4 – ¼” bolts and flat washers supplied. Slide the locking bar through slot cut below access hole
and secure to emergency manual release access cover, using a lock.
NOTE:
USAutomatic strongly recommends the Emergency manual release access cover be securely
locked in place using the locking bar and pad lock (pad lock not supplied)