Tempest remote transceiver – Clear-Com Tempest900 User Manual
Page 77
71
Tempest®900 2-Channel Wireless Intercom System
Buttons on the BeltStation do not function
A number of buttons on the BeltStation can have alternate functions that the user can select.
If a button on the BeltStation is not working as expected, re-confirm all settings and any alternate function assignment
in the menu. The button may have been reassigned wirelessly from the BaseStation or by T-Desk. Confirm that the
function is available for use. If the reassignment involves any GPO, confirm that menu selection, the connections, and
the equipment functionality.
Call Function does not work properly
•
Check to make sure that the CALL function is enabled.
•
Confirm that a TALK button is enabled for the channel that you wish to call.
•
A Call signal will be received by the BeltStation only on the channel(s) that are currently being monitored.
Stage Announe (SA) function does not work properly
The Stage button has two separate functions. Optionally, it controls the shared Stage relay contact on the back of the
BaseStation.
»
When you press the STAGE button it reroutes the BeltStation user’s microphone to the SA output on the back of
the BaseStation.
»
When pressing the STAGE button, if there is no audio present at the SA, confirm that the Stage Announce
function is enabled in the BeltStation.
»
If the SA relay does not close, ensure that the Stage Relay is enabled in the BeltStation. If problems persist,
confirm the operation with another BeltStation.
Tempest Remote Transceiver
Remote Transceiver RX or TX LEDs do not light
While the Transceiver is properly connected to the BaseStation, turn the BaseStation Power Switch to the OFF position.
Wait for 30 seconds and turn the BaseStation Power Switch back to the ON position. This should initialize the Remote
Transceiver. The Config LED should light momentarily and then go out. Once the Config LED goes out the Remote Transceiver
TX LED should light. If there are BeltStations communicating to the BaseStation through the Remote Transceiver the RX LED
should light as well.
When connecting any shared BaseStations to any wired intercom system,
only channels connected to the wired system can be shared. A BeltStation
CALL signal is sent only when the Talk button is enabled.
To manually re-initialize the Transceiver, power OFF the BaseStation for at least
15 seconds and power the BaseStation back ON, with the Transceiver connected.