Tempest®900 2-Channel Wireless Intercom System

BaseStation Setup

Steps to Setup the BaseStation

Choose a location for the BaseStation

Choose an antenna location and configuration

Maximize performance

Configure operation features

Set Network Number and Lockout Key

»

Name each BaseStation and BeltStation (optional, but encouraged)

»

Set Static or Dynamic Display

Configure optional features

Choose a Location

A Tempest BaseStation mounted in an equipment rack with optional cables and mounting hardware.

Tempest is a radio system. Choosing a location for your Tempest BaseStation and the associated antenna is one of the most

important factors to ensure proper system operation and achieve maximum operational range. As covered in the

General

Information

and

Theory of Operation

section of this manual, broadcasting and receiving RF signals can be greatly affected by

physical and electromagnetic barriers.

Following the guidelines below for selecting a suitable BaseStation and antenna location will help to ensure that your

system operates properly and achieves the maximum possible operational range.

See the Antenna Configuration section of this manual for details about recommended cable type and other important

information about connecting the antenna to the Tempest BaseStation.

BaseStation Location

The location of the BaseStation is important, but it is the location of the antenna that will ensure maximum system

performance and operational range. Whenever possible, locate the BaseStation in close proximity to the desired coverage

area. If this is not possible consider using the optional Remote Transceiver to achieve optimal antenna positioning. It is

not recommended to use RF coaxial cable lengths longer than 25 feet to remote the antenna, as this will degrade system

performance and operational range.

The BaseStation must have a source of electric power available. This can be either AC or battery (DC) power.

The front panel of the BaseStation must be accessible for configuration.

The front panel may be used as a communication portal.

The rear panel must be accessed for making wired system connections.

The Tempest BaseStation should be in a location that has adequate ventilation and is not subject to extreme

temperatures and humidity.

Avoid areas subject to water or rain.

Always use a stable and secure platform or rack mount system.