No audio passing when not using an external hardwired intercom system and Tempest BaseStations are

sharing intercom channels.

Confirm that no wired intercoms are connected to the system.

Confirm a 3-pin XLR cable connection for each channel to be shared, between each of the BaseStations.

Set the BaseStation 2-Wire Intercom Type Select Switch to the Clear-Com position.

Select 2-Wire for the relevant channels. Set only

one

of the Tempest BaseStations to Master Mode.

No audio passing when using an external hardwired intercom system and Tempest BaseStations are

sharing intercom channels.

Confirm a 3-pin XLR cable connection for each channel to be shared, between each of the BaseStations.

Set the BaseStation 2-Wire Intercom Type Select Switch to the appropriate position.

Select 2-Wire for the relevant channels.

For each channel to be shared, connect the wired intercom to one of the BaseStations.

Audio can only be passed from one BaseStation to another in the “Clear-Com mode”

unless actually connected to to another type of wired intercom system. Connecting

any wired intercom to any BaseStation will automatically disable Master Mode and

disconnect all shared channels that do not have a wired intercom connected.

When connecting any shared BaseStations to any wired intercom system, only

channels connected to the wired system can be shared.