4. Technical Data Signet 2650 DryLoc Amperometric Electronics

Electrical

Input Specifi cations:

Sensor: Raw signal
Temperature: PT1000 RTD

Output Specifi cations:

Digital (S

3

L):

Serial ASCII, TTL level 9600 bps
Maximum Cable Length:
30 m (100 ft)

Power Supply Input:

Digital (S

3

L) mode:

5 to 6.5 V ± 10% , 3 mA max

Environmental

Storage Temperature:

–20 °C to 85 °C (–4 °F to 185 °F)

Operating Temperature:

0 °C to 85 °C (32 °F to 185 °F). Electronics only

Relative Humidity:

0 to 95%, non-condensing (no electrode connected)

Enclosure Requirements:

NEMA 4X/IP65 with electrode connected

Standards and Approvals

CE
Manufactured under ISO 9001 and ISO 14001

China RoHS (Go to www.gfsignet.com for details)

General

Compatible Sensors:

All Signet Amperometric DryLoc Sensors

Compatible Instruments:

Signet 3-8630-3P Chlorine Transmitter

Mounting:

DryLoc connection

Materials:

Valox

®

(PBT)

Cable:

4.6 m (15 ft) 3 conductor shielded, 22 AWG

Shipping Weight:

0.64 kg (1.14 lb)

Performance

Electronics Accuracy:

< 5 nA or 1% of reading, whichever is greater

@ 25 °C over full input range

Temperature:

± 1.0 °C (PT1000) over full operation range
(when calibrated at ambient temperature)

System Response:

500 ms (update rate)

Operational Range:

± 450 mV

Resolution:

0.1 nA

* Valox

®

is a registered trademark of SABIC Innovative Plastics

3. Wiring

Chlorine Digital (S

3

L) Wiring

Remove approximately 10 mm (0.4 in.) of insulation and tin each conductor before inserting into terminals.

Refer to the wiring diagram above to connect the 2650 cable to the terminals on the

8630

Chlorine

Transmitter.

Maximum cable length is 30 m (100 ft).

Cable should have noise immunity for the sensor signal of up to 30 m (100 ft).

Cable capacitance must be less than 30 pF/foot.

Gnd

I/O

V

+

15
14
13

Signal Ground

Digital (S3L) data

+5 VDC

White

Red

Black

Shield

35.0 mm
(1.38 in.)

61.0 mm
(2.40 in.)

101 mm
(4.0 in.)

Dimensions