Ordering information – GF Signet 2724-2726 pH_ORP Electrodes User Manual
Page 8

Mfr. Part No.
Code
Description
3-2724-00
159 001 545
Electrode, pH, fl at, PT1000, ¾ in. NPT
3-2724-01
159 001 546
Electrode, pH, fl at, PT1000, ISO 7/1 R¾
3-2724-10
159 001 547
Electrode, pH, fl at, 3K Balco, ¾ in. NPT
3-2724-11
159 001 548
Electrode, pH, fl at, 3K Balco, ISO 7/1 R¾
3-2724-HF-10
159 001 771
Electrode, pH, HF resistant, fl at, 3K Balco, ¾ in. NPT
3-2724-HF-11
159 001 772
Electrode, pH, HF resistant, fl at, 3K Balco, ISO 7/1 R¾
3-2726-00
159 001 553
Electrode, pH, bulb, PT1000, ¾ in. NPT
3-2726-01
159 001 554
Electrode, pH, bulb, PT1000, ISO 7/1 R¾
3-2726-10
159 001 555
Electrode, pH, bulb, 3K Balco, ¾ in. NPT
3-2726-11
159 001 556
Electrode, pH, bulb, 3K Balco, ISO 7/1 R¾
3-2726-HF-00
159 001 549
Electrode, pH, HF resistant, bulb, PT1000, ¾ in. NPT
3-2726-HF-01
159 001 550
Electrode, pH, HF resistant, bulb, PT1000, ISO 7/1 R¾
3-2726-HF-10
159 001 551
Electrode, pH, HF resistant, bulb, 3K Balco, ¾ in. NPT
3-2726-HF-11
159 001 552
Electrode, pH, HF resistant, bulb, 3K Balco, ISO 7/1 R¾
3-2726-LC-00
159 001 557
Electrode, pH, bulb, Low Cond, PT1000, ¾ in. NPT
3-2726-LC-01
159 001 558
Electrode, pH, bulb, Low Cond, PT1000, ISO 7/1 R¾
3-2726-LC-10
159 001 559
Electrode, pH, bulb, Low Cond, 3K Balco, ¾ in. NPT
3-2726-LC-11
159 001 560
Electrode, pH, bulb, Low Cond, 3K Balco, ISO 7/1 R¾
3-2725-60
159 001 561
Electrode, ORP, fl at, 10 KΩ
ID, ¾ in. NPT
3-2725-61
159 001 562
Electrode, ORP, fl at, 10 KΩ
ID, ISO 7/1 R¾
3-2734-00
159 001 774
Electrode, pH, fl at, PT1000, ¾ in. NPT **
3-2734-01
159 001 775
Electrode, pH, fl at, PT1000, ISO 7/1 R¾ **
3-2734-HF-00
159 001 776
Electrode, pH, HF resistant, fl at, PT1000, ¾ in. NPT **
3-2734-HF-01
159 001 777
Electrode, pH, HF resistant, fl at, PT1000, ISO 7/1 R¾ **
3-2736-00
159 001 778
Electrode, pH, bulb, PT1000, ¾ in. NPT **
3-2736-01
159 001 779
Electrode, pH, bulb, PT1000, ISO 7/1 R¾ **
3-2736-HF-00
159 001 780
Electrode, pH, HF resistant, bulb, PT1000, ¾ in. NPT **
3-2736-HF-01
159 001 781
Electrode, pH, HF resistant, bulb, PT1000, ISO 7/1 R¾ **
3-2735-60
159 001 782
Electrode, ORP, fl at, 10 KΩ
ID, ¾ in. NPT
3-2735-61
159 001 783
Electrode, ORP, fl at, 10 KΩ
ID, ISO 7/1 R¾
Ordering Information
Ordering Information
2724-2726 and 2734-2736 pH/ORP Electrodes
Accessories and Replacement Parts
Mfr. Part No.
Code
Description
3-2750-1
159 000 744
In-line Sensor Electronics w/Junction Box
3-2750-2
159 000 745
In-line Sensor Electronics w/Junction Box and EasyCal
3-2750-3
159 000 746
Submersible Sensor Electronics with 15 ft cable, ¾ in. NPT threads
3-2750-4
159 000 842
Submersible Sensor Electronics with 15 ft cable, ISO 7/1 R¾ threads
3-2750-7
159 001 671
pH Electronics, Digital (S
3
L), 4.6 m (15 ft) cable
3-2760-1
159 000 939
Submersible Preamplifi er with ¾ in. NPT threads and 4.6 m (15 ft) cable
3-2760-2
159 000 940
Submersible Preamplifi er with ¾ in. ISO threads and 4.6 m (15 ft) cable
3-2760-3
159 000 941
Submersible Connector with 4.6 m (15 ft) cable and ¾ in. NPT threads
3-2760-4
159 000 942
Submersible Connector with 4.6 m (15 ft) cable and ISO 7/1 R¾ in. threads
3-2760-11
159 001 367
In-line Preamplifi er with ¾ in. NPT threads and 4.6 m (15 ft) cable
3-2760-21
159 001 368
In-line Preamplifi er with ¾ in. ISO threads and 4.6 m (15 ft) cable
3-2760-31
159 001 369
In-line Connector with 4.6 m (15 ft) cable and ¾ in. NPT threads
3-2760-41
159 001 370
In-line Connector with 4.6 m (15 ft) cable and ISO 7/1 R¾ threads
3-2759
159 000 762
pH/ORP System Tester (adapter cable sold separately)
3-2759.391
159 000 764
2759 DryLoc Adapter Cable (for use with 2750 and 2760)
3-0700.390
198 864 403
pH Buffer Kit (1 each 4, 7, 10 pH buffer in powder form, makes 50 mL)
3822-7004
159 001 581
pH 4 buffer solution, pint (16 oz) (473 ml)
3822-7007
159 001 582
pH 7 buffer solution, pint (16 oz) (473 ml)
3822-7010
159 001 583
pH 10 buffer solution, pint (16 oz) (473 ml)
3822-7115
159 001 606
20 gram bottle Quinhydrone for ORP calibration
3-2700.395
159 001 605
Calibration kit: 3 Polypropylene cups, box used as cup stand, 1 pint pH 4.01, 1 pint pH 7.00
3-8050.390-1
159 001 702
Retaining Nut, Replacement, Valox
®
, K4530
Georg Fischer Signet LLC, 3401 Aero Jet Avenue, El Monte, CA 91731-2882 U.S.A. • Tel. (626) 571-2770 • Fax (626) 573-2057
For Worldwide Sales and Service, visit our website: www.gfsignet.com • Or call (in the U.S.): (800) 854-4090
For the most up-to-date information, please refer to our website at www.gfsignet.com
3-2724.090 Rev H 11/13 English
© Georg Fischer Signet LLC 2013
**Use with 2750 Sensor Electronics