beautypg.com

12 replacement parts, 1 replacement part sets – Burkert Type 2101 User Manual

Page 34

background image

34

Replacementparts

malfunction

remedial action

Valve is not
sealed

Dirt between seal and valve seat

Installing dirt trap

Seat seal worn

Installing new swivel plate

Flow direction reversed

Observe direction arrow on the body

Medium pressure too high

Observe pressure specifications on the
type label

Pilot pressure too low

Observe pressure specifications on the
type label

Valve is leaking on
the release bore

Packing gland worn

Renew packing gland or replace actuator

Tab. 8: Malfunctions

9)

See “8.4 Pneumatic connection”.

12

replacemenT parTs

WarninG!

risk of injury when opening the actuator!
The actuator contains a tensioned spring. If the actuator is
opened, there is a risk of injury from the spring jumping out!

▶ The actuator must not be opened.

CauTion!

risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable replacement parts may
cause injuries and damage the device and the surrounding area.

▶ Use only original accessories and original replacement parts

from Bürkert.

12.1 replacement part sets

The following replacement part sets are available for the globe valve
Type 2101:
• Valve set

consists of swivel plate with seal, pin and graphite seal.

• Sealing set for packing gland

consists of the individual parts of the packing gland, graphite seal
and lubricant
(the (modified) socket wrench is not included in the sealing set).

english

Type 2101