Installation

control function i:

Connect the control medium to the pilot air port 1 and 2 of the
actuator (see “Fig. 18: Pneumatic connection”)
Pressure on connection 1 opens the valve.
Pressure on connection 2 closes the valve.

1

2

Pilot air port

CFA, CFB, CFI

Air discharge connection

CFA, CFB

Pilot air port CFI

Fig. 18: Pneumatic connection

control air hose:
6/4 mm or 1/4” control air hoses can be used.
Optionally a pilot air port is possible via a G 1/8 thread.

8.5

removal

DanGer!

risk of injury from discharge of medium and pressure!
It is dangerous to remove a device which is under pressure due to
the sudden release of pressure or discharge of medium.

▶ Before removing a device, switch off the pressure and vent the

lines.

procedure:

Loosen the pneumatic connection.

Remove the device.