Technicaldata

7.4

Operating conditions

7.4.1 Temperature ranges

Actuator
size

Actuator
material

Medium
(for PTFE seal)

Environment

2)

ø 50 mm

PPS

-10 – +185 °C

0 – +60 °C

3)

0 – +100 °C

4)

ø 70 mm
ø 90 mm
ø 130 mm

Tab. 1: Temperature Ranges

2)

If a pilot valve is used, the max. ambient temperature is
+55 °C.

The globe valve is suitable for steam sterilization.

3)

Pilot air ports with push-in connector

4)

Pilot air ports with threaded bushing

7.4.2 pressure ranges

Actuator size

Maximum pilot pressure

5)

ø 50 mm

10 bar

ø 70 mm
ø 90 mm
ø 130 mm

7 bar

Tab. 2: Pressure Ranges

5)

For the device version ø 70 / Orifice 50 / MC 13 the
maximum permitted pilot pressure is limited to 7 bar.

english