Maintenance,Cleaning

noTe!

damage to the seat seal or the seat contour!

▶ When installing the actuator, ensure that the valve is in open

position.

Control function A pressurize the pilot air port 1 with com-
pressed air (5 bar): valve opens.

Screw actuator into the valve body.
Observe tightening torque (see “Tab. 6: Tightening torques of
valve body / nipples”
).

1

2

Pilot air port

CFA, CFB, CFI

Air discharge connection

CFA, CFB

Pilot air port

CFI

Fig. 22: Connections

tightening torques of valve body / nipples
Orifice

tightening torque [nm]

13/15

45 ±3

20

50 ±3

25

60 ±3

32

65 ±3

40
50

70 ±3

65

100 ±3

80

120 ±5

100

150 ±5

Tab. 6: Tightening torques of valve body / nipples

If the position of the pilot air ports for installation of the
hoses is unfavorable, these can be aligned steplessly by
rotating the actuator through 360°.