Page 23

background image

2-3

Brooks

®

GF40/GF80/GF81 Devices

Installation and Operation Manual
X-TMF-GF40-GF80-Series-MFC-eng
Part Number: 541B161AAG
June, 2013

Section 2 Installation

a pneumatic pressure test in accordance with applicable vessel codes. To
maintain a device's clean integrity, this service should be performed by the
factory or one of the certified service centers.

2-7 Gas Connections

Prior to installation, ensure that all piping is clean and free from
obstructions. Install piping in such a manner that permits easy access to
the device if removal becomes necessary.

2-8 In-Line Filter

It is recommended that an in-line filter be installed upstream from the device
to prevent the possibility of any foreign material entering the flow sensor or
control valve. The filtering element should be replaced periodically or
ultrasonically cleaned.

2-9 Mechanical Installation

The recommended installation procedure guidelines are as follows:

The device should be located in a clean, dry atmosphere relatively free
from shock and vibration.

Leave sufficient room for access to the user interface and MAC
ID and baud rate switches (if equipped) at the top of the device.

Install the device in such a manner that permits easy purge and removal
if the device requires servicing.

The GF40/GF80 Series also utilizes MultiFlo

®

technology that allows the

user to configure standard configurations ("SAs") or "blanks" for a variety of
pure gases and mixtures. As a result, MultiFlo

®

technology enables the user

to reduce unique inventory requirements.

This manual is related to the following products: