ALLIED Vision Technologies Goldeye P-032 SWIR User Manual
Page 86
Appendix
Goldeye Technical Manual V2.5.0
86
represented in 16 bits fixed point two's complement notation.
See parameter m=
compensation. Changing this parameter may void ex factory
calibration.
p=
User specified parameter for the
temperature drift compensation. This is a value represented
in 16 bits fixed point two's complement notation. The value
is an additional offset value to fine adjust the camera. See
parameter m=
q=
File number of the binary table data for
the temperature dependant mean value correction (see
parameter j=
given as binary value pairs (temperature, M). The correction
interpolates linearly between two sampling points and
extrapolates beyond the edges of the covered temperature
range. Correction data is recorded during the factory
calibration process. Changing this parameter or the specified
file contents may void ex factory calibration.
s=
are activated immediately.
|\| \__|
| | +---b: Baud rate of the main UART and (if
| | availiable) the second channel UART. The
| | second channel UART supports 9600 to 115200
| | Baud only.
| | 0 -> 110 Baud.
| | 1 -> 300 Baud.
| | 2 -> 600 Baud.
| | 3 -> 1200 Baud.
| | 4 -> 2400 Baud.
| | 5 -> 4800 Baud.
| | 6 -> 9600 Baud.
| | 7 -> 19200 Baud.
| | 8 -> 38400 Baud.
| | 9 -> 57600 Baud.
| | A -> 115200 Baud.
| +---------a: Second channel UART configuration. This
| channel is equivalent to the main UART
| concerning the use as command interface.
| But it is not intended to use both UARTs at
| the same time, because they share the same
| receive buffer. Output characters are always
| sent to both channels.
| 00 -> Second channel UART off. The active
| serial communication port is selected
| by hardware jumper settings.
| 01 -> Activate second channel via the frame
| grabber's serial port. This is either
| Camera Link TG/TC or Pleora device
| port serial 0.
| 10 -> Activate second channel via Pleora
| device port bulk 0 (MODE:UART,