beautypg.com

Triggersignalrouting (w), Current parameter settings (y), Show help text (?) – ALLIED Vision Technologies Goldeye P-032 SWIR User Manual

Page 64: Ion see chapter

background image

Goldeye Technical Manual V2.5.0

64

TriggerSignalRouting (W)

Current parameter settings (Y)

The command

Y=1 shows the actual set parameter values.

Show help text (?)

The command

?=1 shows a command reference text at the serial terminal. It

lists a short description for each command available in the firmware.

GigE feature name (CameraSpecialFeatures)

Feature visibility Description

TriggerSignalRouting
(firmware version V3.4.0 and higher)

Guru

CameraHead

The trigger signal is routed
directly to the camera head.
The TriggerSelector feature
can not be set to ExposureStart
in this mode.

PT1000 (default)

The trigger signal is routed to
the Pleora board. This is
necessary to enable the
TriggerSelector functionality.
(See table: Camera standard
feature: AcquisitionControl

on

page 46

.

)

Table 31: GigE feature: TriggerSignalRouting

Note

This function is not available as GigE Vision feature.

Note

This function is not available as GigE Vision feature.