Appendix, Command reference, He appendix: chapter – ALLIED Vision Technologies Goldeye P-032 SWIR User Manual
Page 81: Chapter
Appendix
Goldeye Technical Manual V2.5.0
81
Appendix
Command reference
This chapter describes the general command reference of the Goldeye xy-...
firmware. It can be output to the camera’s serial interface by sending the com-
mand
?=1.
IRC-300CL/GE, IRC-320CL/GE, IRC-340CL/GE, IRC-600CL/GE, IRC-640CL/GE,
NIR-300(F)(P)CL/GE, NIR-600PCL/PGE, NIR-610PCL/PGE;
Pearleye P-007 LWIR, Pearleye P-030 LWIR,
Goldeye (CL/P)-008 SWIR (Cool) and Goldeye (CL/P)-032 SWIR Cool
Series Command Help
===============================================================================
Version...............: Vxx / xx.xx.20xx / AVT GmbH
Referenced Firmware...: Vxx / Vxxxx
General Information
-------------------
Each command consists of a command letter, optionally followed by an equality
sign and a parameter value in hexadecimal number representation. The command
letter is case sensitive. Hexadecimal values are always upper case and are 1 to
4 digits long. The command is activated by sending a carriage return character
([CR], ASCII character number 0x0D). Serial communication operates in echo mode
by default. This means that each character received by the module is echoed
back to the sender.
Example (set Baudrate to 115200 Baud, RS-232 only):
s=A[CR]
After successful execution of the command, the command input character ">" is
output. If any error occurred, somewhere previous to the prompt a question
mark character "?" is displayed.
To query a parameter value, send the corresponding command letter followed by
the equality sign and a question mark character:
s=?[CR]
If the intended action does not need any parameter, it is also sufficient in
most cases - as a shortcut - to send the command letter only, directly followed
by [CR].
Note
The displayed command reference is for both: AVT Goldeye and
AVT Pearleye camera families.
See this command reference to verify, if a command is valid for
your camera model.