ALLIED Vision Technologies Goldeye P-032 SWIR User Manual
Page 45
Data interface
Goldeye Technical Manual V2.5.0
45
The camera can be single triggered or periodically triggered with a fixed frame
rate (t
p
) up to the maximum frame rate of 118 fps (Goldeye xy-008) or 30 fps
(Goldeye xy-032).
Figure 15: Trigger input diagram (TriggerSelector = ExposureActive)
Figure 16: Trigger input diagram (TriggerSelector = ExposureStart)
Goldeye xy-008
Goldeye xy-032
t
P
: Trigger period
t
P
: Trigger period
t
EXP
: Exposure time
t
EXP
: Exposure time
t
TRG
: Exposure start pulse (
μs)
t
TRG
: Exposure start pulse (
μs)
t
R
: Readout time
t
R
: Readout time
t
R
= 8.2 ms (320 x 256)
t
R
= 32.4 ms
t
R
= 5.1 ms (320 x 160)
t
F
: Frame period (t
F
= t
P
)
t
F
: Frame period (t
F
= t
P
)
t
Fc
: Frame period in continuous mode
t
Fc
: Frame period in continuous mode
t
Fc
= 8.45 ms (320 x 256)
t
Fc
= 33.0 ms
Table 20: Trigger input values