beautypg.com

ALLIED Vision Technologies Goldeye P-032 SWIR User Manual

Page 79

background image

Goldeye Technical Manual V2.5.0

79

a: Controls the configuration of the serial port.

e: Controls the echo mode.

x: Controls the baud rate of the serial port.

Example

Set the factory default (115200 Baud and activate serial interface via Camera
Link / Gigabit Ethernet).

>

s=2A[CR]

s 2A

Baud rate

F

E

D

C

B

A

9

8

7

6

5

4

3

2

1

0

-

-

-

-

-

-

-

-

e

a

a

-

x

x

x

x

rw

rw rw

rw rw rw rw

Bit group Value (hex)

Description

x

O

110 Baud

1

300 Baud

2

600 Baud

3

1200 Baud

4

2400 Baud

5

4800 Baud

6

9600 Baud

7

19200 Baud

8

38400 Baud

9

57600 Baud

A

115200 Baud

a

00

RS232 via 15 pin SUB-D only

01

Frame grabber serial port (Camera Link or Pleora device port serial IO)

10

Additionally activate second channel via Pleora device port bulk 0
(MODE:UART) GigE interface only

11

Reserved

e

0

Each character received from the host is echoed back to it

1

No Echo

Table 44: Baud rates: values

Note

This function is not available as GigE Vision feature.

This manual is related to the following products: