SWR

≤ 2.1 GHz

1.4:1 (typ)

(for serial number

> 2.1 GHz to 4 GHz

1.5:1 (typ)

prefix 4742xxxx)

> 4.0 GHz 5.6 GHz

1.7:1 (typ)

> 5.6 GHz to 6 GHz

2.0:1 (typ)

Maximum

Max DC voltage

50 VDC (nom)

reverse power

250 kHz to 6 GHz

2 W (nom)

SWR

≤ 1.4 GHz

1.7:1 (typ)

(for serial number

> 1.4 GHz to 4 GHz

2.3:1 (typ)

prefixes lower than

> 4.0 GHz 5.0 GHz

2.4:1 (typ)

4742xxxx)

> 5.0 GHz to 6 GHz

2.2:1 (typ)

Maximum

Max DC voltage

50 VDC (nom)

reverse power

50 kHz to 6 GHz

2 W (nom)

Absolute level accuracy in CW mode

1

[ALC on]

(for serial number prefix 4742xxxx)

Standard

Option 1EQ

+7

2

to -60 dBm < -60 to -110 dBm

< -110 to -127 dBm

100 kHz to 250 kHz

±0.6 dB

±1.0 dB

---

> 250 kHz to 1 MHz

±0.6 dB

±0.7 dB

±1.7 dB

> 1 MHz to 1 GHz

±0.6 dB

±0.7 dB

±1.0 dB

> 1 GHz to 3 GHz

±0.7 dB

±0.9 dB

±1.4 dB

> 3 GHz to 4 GHz

±0.8 dB

±0.9 dB

±1.0 dB

> 4 GHz to 6 GHz

±0.8 dB

±1.1 dB

±1.3 dB

Absolute level accuracy in CW mode

1

[ALC on]

(for serial number prefixes lower than 4742xxxx)

Standard

Option 1EQ

+7 to -60 dBm

< -60 to -110 dBm

< -110 to -127 dBm

250 kHz to 1 MHz

±0.6 dB

±0.7 dB

±1.7 dB

> 1 MHz to 1 GHz

±0.6 dB

±0.7 dB

±1.0 dB

> 1 GHz to 3 GHz

±0.7 dB

±0.9 dB

±1.4 dB

> 3 GHz to 4 GHz

±0.8 dB

±0.9 dB

±1.0 dB

> 4 GHz to 6 GHz

±0.8 dB

±1.1 dB

±1.3 dB

1. Quoted specifications between 20 and

30 °C. For temperatures outside of this

range, absolute level accuracy degrades

by 0.01 dB/ °C for frequencies ≤ 4.5 GHz

and 0.02 dB/ °C for frequencies

> 4.5 GHz.

2. Level accuracy specified to +7 dBm or

maximum specified output power, which-

ever is lower.

Maximum available output power

Frequency (MHz)

Max output power (dBm)

0

1000

2000

3000

4000

5000

6000

18

17

16

15

14

13

12

11

10