Chapter 6: specifications – Alpha Technologies Celltron Essential CTE-1200 AT; CTE-2200 AT; CTE-3200 AT User Manual
Page 39

33
Chapter 6: Specifications
Model Number:
CTE-1200 AT; CTE-2200 AT; CTE-3200 AT
Power Requirements:
One 9-volt high capacity/heavy duty lithium
battery or rechargeable battery pack accessory
Applications:
Tests individual lead acid cells or monoblocs
(6, 12 volts) in any common configuration
Environmental Operating Range:
0 to +40°C, 95% relative humidity,
non-condensing
Voltage:
1.0–15.0 volts DC
Storage Temperature:
–20 to 82°C
Conductance:
100–9,999 siemens
Over Voltage Protection:
•
Fused protection to 60 volts DC
•
Reverse polarity protected
Test Data Storage:
Up to 4 strings per site
Housing Material:
Acid-resistant ABS plastic
Accuracy:
+ 2% across test range
Analyzer Dimensions:
9 in x 4 in x 2.5 in
230 mm x 102 mm x 65 mm
Voltmeter Resolution:
10 mV DC
Case Dimensions:
19 in x 15.5 in x 5 in
750 mm x 610 mm x 200 mm
User Programmable Functions:
•
Low voltage alarm setting
•
Low conductance warning
•
Low conductance failure
•
Day/date/time formats (USA/international)
•
Test mode (auto start)
Analyzer Weight:
1 lb / 500 gm
Shipping Weight: CTE-3200 AT Kit
9.5 lb / 4 kg
Calibration:
Auto-calibration prior to every test; no future
calibration required
Special Features:
•
Impact-resistance tested
•
Connection interfaces tested for durability
and endurance
•
No-Ox grease petroleum product resistance
Test Cable Options:
•
Dual contact clamps
•
Dual contact probes
•
Custom cables by quotation