beautypg.com

ABUS FU8211 Secvest 2WAY Wireless Universal Module User Manual

Page 39

background image

35

4.4 Keys
The keys are required for programming and navigation in the
programming menu. They have the following meanings:

SELECT: Press to start programming or to select another

function during programming.

SET:

Press to confirm the selected function during
programming.

ESC/DEL: Press to end programming or to delete a selected

function during programming.

4.5 Dip

switches

Some dip switches have different meanings depending on the
function of the accessory module. Some meanings are the same
for all functions. They have the following meanings:

1. OFF: The accessory module trains wireless transmitters via

infrared LED only.

ON: The accessory module trains wireless transmitters via

wireless protocol only.

2. OFF: The accessory module does not monitor jamming.
ON: The accessory module transmits a fault message in the

event of jamming. In function mode 6, relay 4 is activated
in the event of malfunctions.

3. OFF: The accessory module does not monitor the detectors

for supervision.

ON: The accessory module transmits a fault in case of a

supervision failure and sends a supervision message. In
function mode 6, relay 4 is activated in the event of a
supervision fault.

4. OFF: Short supervision time (20 minutes).
ON: Long supervision time (3 hours).
5. OFF: The inputs on the accessory module must be wired

without a resistor (NC).

ON: The inputs of the accessory module must be wired with a

2.2 kΩ resistor (EOL).

6. OFF: Input 1 of the accessory module works as an NC

contact.

ON: Input 1 of the accessory module works as an NO

contact.

7. OFF: Input 1 works as an input for key switches (imp).