Section 2: Installation of the X144 e-FlowMeter

2.1 - Installation Locations:

For optimum performance, it is recommended that the valve in which the X144 e-FlowMeter is installed be

located as shown in the “Optimum Installations” illustration below, Figure 2-1.

CAUTION:

Valve in which X144 e-FlowMeters are installed MUST have upstream and downstream Isolation

Valves to ensure that the line is locked out and under pressure during installation, maintenance or removal of

the X144 e-FlowMeter.

> 5 Pipe Diameters

Either Inlet Tapping

pump

Optimum Installations

Unacceptable Installations

CLA-VAL

In Inlet Tapping

CLA-VAL

Downstream

of an Elbow

CLA-VAL

Outside Elbow

CLA-VAL

Pipe Reducer Upstream

CLA-VAL

Isolation Valve MUST be Wide Open or

5 pipe diameters upstream

CLA-VAL

(top view)

(top view)

In Outlet Tapping

Downstream of
Double Elbow

Inside of

an Elbow

(top view)

1 to 5 Pipe

Diameters

Outside

or Inside

(top view)

On Discharge

of a Pump

CLA-VAL

pump

(vertical rise)

Figure 2-1: Installation Guidelines

5

Note: Do not use with 40 Series Rate-of-Flow Controllers with orifice on inlet