Installation and operation, cont’d, Front panel security lockout (executive mode) – Extron Electronics USP 405 User Guide User Manual
Page 36
Installation and Operation, cont’d
USP 405 • Installation and Operation
2-20
The Adjust knobs have no mechanical limits to their rotation.
• Centering: Horizontal (Horz) adjusts horizontal positioning.
Vertical (Vert) adjusts vertical positioning.
• Sizing: Horizontal (Horz) adjusts horizontal sizing.
Vertical (Vert) adjusts vertical sizing.
• Brightness/Contrast: Brightness adjusts from 0 to 63.
Contrast adjusts from 0 to 255.
• Color/Tint: Color adjusts from 0 to 127.
Tint adjusts from 0 to 255.
• Zoom: Adjust zoom by observing the display and turning either
adjustment knob either clockwise (zoom in) or counterclockwise
(zoom out). The image increases/decreases in size both
horizontally and vertically.
• Detail: Detail adjusts image sharpness from 0 to 7.
The USP 405 times out to the default menu after 10 seconds.
4.
Repeat steps 2 and 3 for each image adjustment to be made for that input.
The LCD display may show that an adjustment is “Not Available” in place
of a number if that adjustment does not apply to the input’s video format.
The following input types display “Not Available” during certain picture
adjustments; all other input types have full picture adjustments:
Input 1
RGB: no color and no tint, anytime
Input 2
RGB, RGBcvS: no color or tint anytime; YUVi, YUVp, Betacam 50,
Betacam 60, composite (PAL), S-video (PAL) and HDTV: no tint (but there is
color)
Input 3
composite (PAL): no tint (but there is color)
Input 4
S-video (PAL): no tint (but there is color)
Input 5
(SDI): no color, no tint, no detail
Front Panel Security Lockout (Executive mode)
To prevent accidental changes to settings, press the Size and Zoom buttons
simultaneously for 2 seconds to enable the USP 405’s front panel security lockout
(Executive mode). Executive mode locks all front panel functions except input
selection and the Freeze button. The menu system still returns to the default
cycle when 10 seconds have elapsed. The USP 405’s front panel and the IR 801
are both affected by Executive mode. When Executive mode is active, all
functions and adjustments can still be made through RS-232 control. For details
on RS-232 control, see chapter 3.
To disable the Executive mode, press the Size and Zoom buttons simultaneously
for 2 seconds.
10 sec.
timeout
Press for
2 seconds simultaneously*
Press for
2 seconds simultaneously*
Executive Mode
Enabled
Executive Mode
Disabled
10 sec.
timeout
*Executive mode can be enabled
or disabled from any menu
SIZE
ZOOM
SIZE
ZOOM
Default
Cycle
Default
Cycle