beautypg.com

Sis commands, Commands – Extron Electronics PoleVault Systems PVS 305SA User Manual

Page 45

background image

SIS Command/Response Table

Command

ASCII (Telnet)

(host - switcher)

Response

(switcher to host)

Video Configuration

Set the video signal type

X!* X2# \

TypX!= X2#]

View the video signal type

X! \

TypX!= X2#]

Status Commands

View all input status

LS

Frq= X2$* X2$* X2$* X2$]

View paging sensor status

42S

Sts42*X#]

Mic Talk-over Threshold

Adjust talk-over threshold

2* X2% #

ThrX2%]

Decrement threshold

-* 2#

ThrX2%]

Increment threshold

+* 2#

ThrX2%]

View mic threshold

2#

ThrX2%]

Program Audio Ducking Level

Adjust audio ducking level

58 * X2^#

AdlX2^]

Increment audio ducking

+* 58#

AdlX2^]

Decrement audio ducking

-* 58#

AdlX2^]

View audio ducking

58#

AdlX2^]

Set Lineout Mode

Set lineout to variable

55*1#

LineOut*X2&]

Set lineout to fixed

55*2#

LineOut*X2&]

View lineout mode

55#

LineOut*X2&]

Set Audio Output Mode

Set audio output mode to mono

18*1#

PreAmpMod*X@]

Set audio output mode to stereo

18*2#

PreAmpMod*X@]

Set Output Volume Level

Specify volume

X^V

VolX^]

Increment volume

+V

VolX^]

Decrement volume

-V

VolX^]

View volume

V

VolX^]

Paging Sensor Delay

Set paging sensor delay

75 * X2(#

PageDly*X2(]

View paging sensor delay

75#

PageDly*X2(]

]

= CR/LF (carriage return/line feed) (hex 0D 0A)

}

= CR (no line feed)

= Space

E

= Escape key

X! = Input numbers 1 through 4, and 7;

0 = all outputs muted (both audio and video)

1 and 2 = RGB inputs

3 and 4 = Composite video inputs

X@ = Audio mode

1 = Dual mono (default)

2 = Stereo

X# = Status

0 = Off

1 = On

X^ = Volume, 0 - 100, default = 50

X2# = Video type (inputs 3 and 4 only)

1 = Composite video (default)

2 = RGB

X2$ = Video signal status

1 = A video signal present

2 = No video signal detected

X2% = 0 to 15 microphone talk-over threshold level range,

default = 6

X2^ = 0 to 30, program audio ducking level in talk-over mode,

default = 15

X2& = Lineout status

1 = variable (default)

2 = fixed

X2( = Paging delay on 1 second steps; default = 0 (disabled),

1 = 1.0 second, 2.0 = 2 second, ..., 8 = 8.0 second

PVS 305SA specific symbol definitions

N

For a complete list of SIS commands for the PVS 305SA, refer to the PVS 305SA User’s Manual available online at

www.extron

.

com

SIS

Commands

For full PoleVault device specifications, optional accessories, and part numbers, visit

www.extron.com

5-1

PoleVault Systems Installation • Basic SIS Commands