4-2
PoleVault Systems Installation • Reference Information
Regulatory compliance
Safety ................................... CE, c-UL, UL UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke
release, excluding the power supply; meets UL 60065 for safety.
EMI/EMC .......................... CE, C-tick, FCC Class B, ICES, VCCI
Environmental ................... Complies with the appropriate requirements of RoHS, WEEE
Vibration ........................................ ISTA 1A in carton (International Safe Transit Association)
MTBF ............................................... 30,000 hours
Warranty ......................................... 3 years parts and labor
MLC 104 IP Plus
Power .............................................. Supplied by the PVS 305SA twisted pair receiver/switcher
Power input requirements ........... 12 VDC, 0.19 A (0.305 A if used with an optional IRCM-DV+)
Temperature/humidity ................ Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
Rack mount .................................... Wall and furniture mountable
Enclosure type ............................... Plastic faceplate, metal rear
Enclosure dimensions ................... MLC 104 IP Plus faceplate 4.5" H x 4.6" W x 0.1" D (11.4 cm H x 11.7 cm W x 0.3 cm D)
MLC 104 IP Plus device 2.7" H x 3.4" W x 1.8" D (6.9 cm H x 8.6 cm W x 4.6 cm D)
(Depth excludes knob and buttons. Fits some 2 gang boxes. Allow at least 1.9" [4.8 cm] depth
in the wall or furniture.)
Product weight .............................. 1.9 lbs (0.9 kg)
Vibration ......................................... ISTA 1A in carton (International Safe Transit Association)
Regulatory compliance
Safety ................................... CE, c-UL, UL
EMI/EMC .......................... CE, C-tick, FCC Class A, ICES, VCCI
Accessibility ................................... Complies with the appropriate requirements of Section 508 of the Rehabilitation Act
(29U.S.C.794d)
MTBF ............................................... 30,000 hours
PVT CV D, PVT RGB D and PVT RGB D Plus
Power .............................................. Supplied by the PVS 305SA twisted pair receiver/switcher
Power input requirements ........... 5 VDC, 0.10 A for PVT CV D; 5 VDC, 0.15 A for PVT RGB D
Temperature/humidity ................ Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
Mount..............................................
Wall or furniture mountable with included Decora wall plate.
Enclosure type ............................... Plastic
Enclosure dimensions ...................
PVT CV and PVT RGB D Plus:
Faceplate: 2.8" H x 1.6" W x 0.2" D (7.1 cm H x 4.1 cm W x 0.5 cm D)
(fits the opening in a 1 gang Decora plate)
Device: 2.7" H x 1.7" W x 1.4" D (6.9 cm H x 4.3 cm W x 3.6 cm D)
(Depth excludes connectors, height excludes mounting tabs.)
PVT RGB D:
Faceplate: 2.6" H x 1.3" W x 0.3" D (6.6 cm H x 3.3 cm W x 0.7 cm D)
(fits the opening in a 1 gang Decora plate)
Device: 2.6" H x 1.6" W x 0.7" D (6.6 cm H x 4.1 cm W x 1.8 cm D)
(Depth excludes connectors, height excludes mounting tabs.)
Product weight
............................ 0.2 lbs (0.1 kg)
Vibration ......................................... ISTA 1A in carton (International Safe Transit Association)
Regulatory compliance
Safety ................................... CE, c-UL, UL
EMI/EMC .......................... CE, C-tick, FCC Class A, ICES, VCCI
MTBF ............................................... 30,000 hours
N
All nominal levels are at ± 10%
N
Specifications are subject to change without notice.