beautypg.com

Install wall plates, Extron pvt rgb d plus – Extron Electronics PoleVault Systems PVS 305SA User Manual

Page 23

background image

2-12

PoleVault Systems Installation • Installation — Stage 2

3. Install wall plates

a.

Connect the CAT 5 cables to the rear of the input devices

(for RGB devices, connect cable labeled A to port A and

cable B to port B).

b.

If desired, for PVT RGB D Plus plates, use a three

conductor audio cable and connect the audio return to

the connector marked G (ground wire), R (black wire),

and L (red wire). The other end will be connected to the

“Line Out” connection on the PVS 305SA switcher.

c.

If desired wire the IR connection using a two conductor

cable. Wire the ground to G and signal lead to S. The

other end will be connected to the “IR Out” port of the

MLC 104 IP Plus controller.

d.

Mount each device into the mud ring, using the supplied

screws.

e.

Attach the supplied Decora faceplate.

f.

Label the Decora plate with the supplied label, using the

appropriate input number. This makes inputs easier to

identify when configuring the switcher.

g.

Repeat steps a-f for other wall plates.

3a

Connect the cables to the A/V source

input devices at each location.

COMPUTER IN

AUDIO

MONIT

OR OU

T

IR OUT

S

G

IN OU

T

Decora

®

Faceplate

Extron
PVT RGB D Plus

Wall

Wall Mounting

Bracket (mud ring)

3b

Mount the PVT in the mud ring, then

3c

attach the Decora faceplate.