Cut the ceiling tile, Preliminary safety hardware installation, Installation — stage one, cont’d – Extron Electronics PoleVault Systems PVS 305SA User Manual
Page 16
PoleVault Systems Installation • Installation — Stage 1
2-5
Installation — Stage One, cont’d
4. Cut the ceiling tile
a.
Mark the location of the PCM 340 on the T-frame. This
aids putting it back in the correct location when the tile is
replaced.
T
Mark the screen direction on back of the tile (e.g. with
an arrow or “to front”) to help orientation of tile when
replacing it after cutting.
b.
Measure the distances X and Y (see figure) from the inner
vertical section of the front and left T-frame runners to
the center of the Pipe Adapter Plate.
c.
Using the X and Y dimensions, mark and cut a hole for
the slotted pipe in the ceiling tile.
T
Place the tile on a box and mark the hole’s center on
the underside of the tile. Use a hole saw bit to start to
cut the hole by hand (turning bit counter clockwise) to
avoid damaging the tile. When the drill bit is through
the tile, turn the tile over and finish cutting from the
top side.
5. Preliminary safety hardware installation
a
. Mark and drill holes at 10 degrees out from vertical for
each turnbuckle. Drill a fifth hole directly centered above
the PCM 340 for the safety cable.
b.
Install an appropriate anchors or lag eye bolt for the
structural ceiling into each drilled hole.
T-bar
X"
Y"
Minimum and
Maximum
Throw Distance Marks
4b
Take measurements with the PCM 340
on the T-frame
4c
Mark and start cutting the hole on the
underside. Finish on the top side.
Underside of Tile
Top Side of Tile
5a
Mark structural ceiling for lag eye
bolt installation