beautypg.com

Extron Electronics IPL T PC1i User Guide User Manual

Page 67

background image

Command

ASCII (Telnet)

(Host to Switcher)

URL Encoded (web)

(Host to Switcher)

Response

(Switcher to Host)

Event Control (continued)
Write string to event buffer
memory

24,27

E

string

*

X3%

,X3^,X3&

FE}

W

X3(

%2A

X3%

%2C

X3^

%2C

X3&

FE}

Evt

X3%

,

X3^

,

X3&

,string

]

NOTES:

F must be capitalized in order for strings to be read and written to event buffer memory.

The response to the Write Event command is padded with leading zeros for

X3%

and

X3&

.

X3%

is 5 digits and

X3&

is 10 digits.

The Write String command requires a string beginning with

E

. Strings returned by the device (read or write

response) are binary data (without an

E

).

Start events

24,27

E

1AE

}

W

1AE

|

Ego

]

Stop events

24,27

E

0AE

}

W

0AE

|

Est

]

Query number of events running

E

AE

}

W

AE

|

nnnnn

]

(5-digit number)

With tagged response –
verbose modes 2 and 3:
Enm

nnnnn

]

(5-digit number)

Reset (Zap) and Erase Commands

NOTE:

None of the following zap commands (ZFFF, ZXXX, ZY, or ZQQQ) reset the AC power receptacle. Power remains
in its current state.

Erase all files from user flash
memory

24

E

ZFFF

}

W

ZFFF

|

Zpf

]

Reset all device settings to factory
default

24

E

ZXXX

}

W

ZXXX

|

Zpx

]

NOTE:

This reset is product-dependent. It resets receptacle name and lock mode to Off. It does not reset IP settings such as
IP address, subnet mask, gateway IP address, and IP security level table; and it does not remove the user file system.

Absolute system reset; retain IP
address

E

ZY

}

W

ZY

|

Zpy

]

NOTE:

This reset is the same as ZQQQ

(below),

except that it excludes IP settings such as IP address, subnet mask, gateway

IP address, unit name, DHCP, and port mapping (Telnet, web, and Direct Access) in order to preserve communication
with the device. It also erases the user file system. This reset is recommended to be used after a firmware update.

Absolute system reset

24

E

ZQQQ

}

W

ZQQQ

|

Zpq

]

NOTE:

This is a mode 5 reset (see “

Resetting

” in the “Front Panel Features and Operation” section). It resets all device

settings to the factory defaults; however, the firmware version remains the same.

IPL T PC1 • SIS Programming and Control

61

This manual is related to the following products: