beautypg.com

Extron Electronics IPL T PC1i User Guide User Manual

Page 59

background image

X5(

=

IR Playback mode

0 = play once

1 = play continuously

Response is returned with leading zeros.
To stop mode 1 playback, send the IR command again with mode 0 selected.

X6$

=

Time in seconds to keep sending the broadcast message (0-255, default = 10)

X6(

=

(Ethernet only) Number of seconds before timeout on IP connections (min. = 1, max. = 6500, and

default = 30 = 300 seconds).
If no data is received during the timeout period, the Ethernet connection is closed. Each step is 10 seconds. The

response is returned with leading zeros.

X7)

=

The number (as an optional parameter) that is inserted into the e-mail message if the .eml file has an embedded

command (with no parameters).

X7!

=

Hardware (MAC) address: the four most significant hex nibbles converted into a single 16-bit decimal number.

X7@

=

Hardware (MAC) address: the eight least significant hex nibbles converted into a single 32-bit decimal number.

NOTE:

This can be up to 10 digits.

X7#

=

E-mail account user name. Maximum length is 31 characters. This parameter is optional; commas cannot be used as

placeholders for it. If it is omitted from an issued command, any existing user account name is cleared.

X7$

=

E-mail account password. Maximum length is 31 characters. This parameter is optional; commas cannot be used as

placeholders for it. If it is omitted from an issued command, any existing user account password is cleared.

X71!

=

Days of the week

1 = Sunday

2 = Monday

3 = Tuesday

4 = Wednesday

5 = Thursday

6 = Friday

7 = Saturday

X71@

=

Time in minutes (0-1440)

0 = 12 am (midnight)

1440 = clear schedule

Example: 1439 = 11:59
Use the following formula (in 24-hour time format): (hour x 60) + minutes = time in minutes

X71#

=

Power receptacle name (12 characters maximum)

IPL T PC1 • SIS Programming and Control

53