beautypg.com

Symbol definitions – Extron Electronics IPL T PC1i User Guide User Manual

Page 56

background image

Symbol Definitions

]

= CR/LF (carriage return + line feed) (hex 0D 0A)

}

= Soft carriage return (no line feed, hex 0D)

(For web browser commands, use the | [pipe] character instead of the soft return.)

|

= Pipe (vertical bar) character

= Space

24

= The

24

superscript indicates commands that give an E24 (privilege violation) message if you are not logged in at the

administrator level.

E

= Escape key (hex 1B) (For web browsers, use W instead of E. )

X!

= Power receptacle (1-4)

X#

= Greenwich Mean Time (GMT) offset value

(-12.00 to +14.00) represents the time difference in hours and minutes (±hh:mm) relative to Greenwich, England. The
plus sign and leading zero are optional. For example, 5:30 = +05:30.)

X%

= On or Off status

0

= off or disable

1

= on or enable

X^

= Dirty memory status

1

= RAM needs to be saved to flash memory.

0

= RAM has been saved to flash (OK to power off or reset)

.

X(

= Current threshold sense

0

= clear or none

1

= standby

2

= full

(Full threshold must be set before standby.)

X1)

= Group number

0

= none

1 = yellow

2 = green

3 = red
(The exponent designates the port number. The color relates to setting groups via the front panel.)

X1!

= Version (typically listed to two decimal places, that is, n.nn)

X1@

= Unit name. The name of the PC1 is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9),

and minus sign or hyphen (

-

). No blank or space characters are permitted as part of a name. No distinction is made

between upper and lower case.

NOTE:

The first character must be a letter. The last character must not be a minus sign or hyphen.

X1#

= Local date and time format

Set format (MM/DD/YY-HH:MM:SS).

Example: 11/18/03-10:54:00.

Read format (day of week, day month year HH:MM:SS).

Example: Tue,

18

Nov

2011

18:19:33.

X1$

= IP address (nnn.nnn.nnn.nnn

)

. Leading zeros in each of four fields are optional in setting values, and they are

suppressed in returned values.

X1%

= E-mail domain name (for example: extron.com)

X1^

=

Power-up delay between ports in 1/3-second increments. 1-255 permitted.
(Default is 3, which equals 1 second.)

IPL T PC1 • SIS Programming and Control

50

This manual is related to the following products: