Symbol definitions – Extron Electronics IPL T PC1i User Guide User Manual
Page 56
Symbol Definitions
]
= CR/LF (carriage return + line feed) (hex 0D 0A)
}
= Soft carriage return (no line feed, hex 0D)
(For web browser commands, use the | [pipe] character instead of the soft return.)
|
= Pipe (vertical bar) character
•
= Space
24
= The
24
superscript indicates commands that give an E24 (privilege violation) message if you are not logged in at the
administrator level.
E
= Escape key (hex 1B) (For web browsers, use W instead of E. )
X!
= Power receptacle (1-4)
X#
= Greenwich Mean Time (GMT) offset value
(-12.00 to +14.00) represents the time difference in hours and minutes (±hh:mm) relative to Greenwich, England. The
plus sign and leading zero are optional. For example, 5:30 = +05:30.)
X%
= On or Off status
0
= off or disable
1
= on or enable
X^
= Dirty memory status
1
= RAM needs to be saved to flash memory.
0
= RAM has been saved to flash (OK to power off or reset)
.
X(
= Current threshold sense
0
= clear or none
1
= standby
2
= full
(Full threshold must be set before standby.)
X1)
= Group number
0
= none
1 = yellow
2 = green
3 = red
(The exponent designates the port number. The color relates to setting groups via the front panel.)
X1!
= Version (typically listed to two decimal places, that is, n.nn)
X1@
= Unit name. The name of the PC1 is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9),
and minus sign or hyphen (
-
). No blank or space characters are permitted as part of a name. No distinction is made
between upper and lower case.
NOTE:
The first character must be a letter. The last character must not be a minus sign or hyphen.
X1#
= Local date and time format
Set format (MM/DD/YY-HH:MM:SS).
Example: 11/18/03-10:54:00.
Read format (day of week, day month year HH:MM:SS).
Example: Tue,
18
Nov
2011
18:19:33.
X1$
= IP address (nnn.nnn.nnn.nnn
)
. Leading zeros in each of four fields are optional in setting values, and they are
suppressed in returned values.
X1%
= E-mail domain name (for example: extron.com)
X1^
=
Power-up delay between ports in 1/3-second increments. 1-255 permitted.
(Default is 3, which equals 1 second.)
IPL T PC1 • SIS Programming and Control
50