RS-232 port

From the drop-boxes in the port type section, you can select the baud rate, data bits, parity,
stop bits, and flow control for the PC1 serial COM port.
Click

Submit

to enter your selections.

If you click

Cancel

before submitting your selections, your entries are reset to the last saved

parameters.
Defaults are:

Baud Rate:

9600

Data Bits:

8

Parity:

None

Stop Bits:

1

Flow control:

None

AC receptacle

In the AC Receptacle Settings section, you can do the following:

Enter a name for the receptacle, which could reflect the output device connected to
it, the room in which the device is located, and so forth. The name can be 1 to 12
characters. The following characters are not permitted:

# % + = ~ ` : ; “ ‘ , . | \

By default, the receptacle is named Receptacle 1.

Select the

On

or

Off

radio button to power the connected device on or off.

Click

Submit

to implement your changes. If you click

Cancel

before submitting your

selections, your entries are reset to the last saved parameters.

Using the IR Drivers page

The IR Drivers page lets you view the IR drivers that have been uploaded to the PC1 via the
File Management page (see “

Managing Files

,” later in this section). You can also view

the commands contained within the IR driver, and cause the connected output device to
perform (“play”) any of the listed commands.
For an IR driver to appear on this page, you must rename its file to a number with an
.eir extension (for example,

1.eir

,

2.eir

, and so forth) before uploading it via File

Management. When the driver is displayed on the IR Drivers page, its device name also is
displayed.

Figure 20.

IR Drivers Page

IPL T PC1 • HTML Configuration and Control