beautypg.com

Command and response table for sis commands, Command and response table for sis, Commands – Extron Electronics IPL T PC1i User Guide User Manual

Page 60

background image

Command and Response Table for SIS Commands

Command

ASCII (Telnet)

(Host to Switcher)

URL Encoded (web)

(Host to Switcher)

Response

(Switcher to Host)

Power Receptacle Control / Current Sense
Turn receptacle power on

E

1*1PC

}

W

1

%2A

1PC

|

Cpn

01

Ppc1

]

Turn receptacle power off

E

1*0PC

}

W

1

%2A

0PC

|

Cpn

01

Ppc0

]

View receptacle power status

E

1PC

}

W

1PC

|

X%

]

Set Executive mode on

1X

1X

Exe1

]

Set Executive mode off

0X

0X

Exe0

]

View Executive mode

X

X

X%

]

Power Receptacle Naming
Set receptacle name

24

E

1,

X71#

NO

}

W

1

%2C

X71#

NO

|

Nmo1,

X71#

]

Set receptacle name to factory
default

24

E

1,

NO

}

W

1

%2C

%20

NO

|

Nmo1,

X71#

]

View receptacle name

E

1NO

}

W

1NO

|

X71#

]

Power Receptacle Scheduling

Set scheduling

24

E

1*

X71!

*

X%

*

X71@

SS

}

W

1

%2A

X71!

%2A

X%

%2A

X71@

SS

Set1*

X71!

*

X%

*

X71@

]

View scheduling

E

1*

X71!

*

X%

SS

}

W

1

%2A

X71!

%2A

X%

SS

|

X71@

]

Front Panel Lockout Scheduling (Executive Mode)

Set scheduling

24

E

2*

X71!

*

X%

*

X71@

SS

}

W

2

%2A

X71!

%2A

X%

%2A

X71@

SS

Set2*

X71!

*

X%

*

X71@

]

View scheduling

E

2*

X71!

*

X%

SS

}

W

2

%2A

X71!

%2A

X%

SS

|

X71@

]

Ethernet Data Port Commands
Set current connected port
timeout

E

0*

X6(

TC

}

W

0

%2A

X6(

TC

|

Pti0*

X6(

]

View current connected port
timeout

E

0TC

}

W

0TC

|

X6(

]

Set global IP port timeout

E

1*

X6(

TC

}

W

1

%2A

X6(

TC

|

Pti1*

X6(

View global IP port timeout

E

1TC

}

W

1TC

|

X6(

]

Information Requests

NOTE:

An asterisk (*) after a version number indicates the version that is currently running. Question marks (?.??)
indicate that only the factory firmware version is loaded. A caret (^) indicates the firmware version that should be
running; however, a mode 1 reset was executed and the factory default firmware version is currently loaded. An
exclamation point (!) indicates corrupted firmware.

Query firmware version

Q

Q

X1!

]

With tagged response –
verbose modes 2 and 3:
Ver01*

X1!

]

Query verbose version information

0Q

0Q

Sum

of

responses

from

2Q, 3Q, and 4Q

]

With tagged response –
verbose modes 2 and 3:
Ver00*

X1!

sum of

responses from 2Q,

3Q, and 4Q

]

Query firmware information

1Q

1Q

X1!

]

With tagged response –
verbose modes 2 and 3:
Ver01*

X1!

]

IPL T PC1 • SIS Programming and Control

54