beautypg.com

Output configuration commands, Output scaler rate sis commands, Ed timings) (see the – Extron Electronics DSC HD-3G A User Guide User Manual

Page 60: Output edid command, Input presets commands

background image

Command

ASCII Command

(Host to Scaler)

Response

(Scaler to Host)

Additional Description

Presets (continued)

Input Presets

Recall preset

2 *

X2^

.

2 Rpr

X2^

]

Recall input preset

X2^

for

selected input.

Save preset

2 *

X2^

,

2 Spr

X2^

]

Save input preset

X2^

for

selected input.

Delete/clear preset

E

X 2 *

X2^

PRST

}

Prst X 2 *

X2^

]

Clear input preset

X2^

and set

its name to [unassigned].

Input Preset Name

Write name

E

2 *

X2^

,

X1$

PNAM

}

Pnam 2 *

X2^

,

X1$]

Set the name of input preset

X2^

to

X1$

.

Read name

E

2 *

X2^

PNAM

}

X1$

]

In verbose modes 2 and 3:
Pnam 1 *

X2%

,

X1$

]

View the name of input preset

X2^

.

NOTE:

Unnamed presets are shown as [unassigned]. To restore a default input preset name, enter a single space

character for

X1$

. These entries are valid only for previously saved presets.

Output Configuration

Output EDID (DSC 3G-HD A only)

Save output EDID

E

S 1

X2!

EDID

}

Edid S 1 *

X2!

]

Save the EDID of the current
DSC 3G-HD A output to

X2!

.

Output Scaler Rate

Set output rate

E

X2)

RATE

}

Rate

X2)

]

Select the DSC 3G-HD A
output resolution and refresh
rate.

View output rate

E

RATE

}

X2)

]

Rate

X2)

]

Show selected output rate.

NOTE:

X1$

= Preset name, up to 16 characters

X2)

= Output resolution and refresh rate:

DSC 3G-HD A: 1 – 92.

1 = EDID of connected HDMI display, 2 = Custom rate 1, 3 = Custom rate 2, 4 = Custom rate 3,

9 = Match the input rate (if the current input is not a valid output rate, defaults to 720p @ 60 Hz [73]).

For variables 11-92, see the

DSC 3G-HD A variables table

on page 44.

DSC HD-3G A: 0 – 96.

0 = Automatic: matches current output resolution (default), 1 = Custom rate 1, 2 = Custom rate 2,

3 = Custom rate 3, 9 = Match the input rate.

For variables 65-96, see the

DSC HD-3G A variables table

on page 45.

Response is 2 digits padded with a zero.

X2!

= EDID emulations: 0 = Automatic: matches current output resolution (default),

1 = Custom EDID 1, 2 = Custom EDID 2, 3 = Custom EDID 3, 9 = Match the input rate.

For

variables

11-96, see the

SIS EDID table

on page 45.

Response is 2 digits padded with a zero.

X2^

= Input preset number: 1 – 128. Response is 2 digits padded with a zero.

DSC 3G-HD A and DSC HD-3G A • Remote Configuration and Control

54

This manual is related to the following products: